7.8 Settings table (configuration)

All the settings which you can perform on drives are described in the following table.
Configurations marked with this symbol can sometimes pose a danger to persons or
damage the drives or other objects if the setting is incorrect.
Code
Determine the addresses for the connected controllers:
0
= Off (if the controller is used independently)
113
1
= Master (address of the first controller). Declare the controller as the master.
2-8
= Slave (addresses of the remaining connected controllers). Declare the
controller as the slave.
Set the number of slave controls in the bus system. Only slave controllers are
123
counted. The master controller is not counted.
Default height for the display: set which value is to be shown in the hand
switch display with the drive retracted. To be able to use the default table
height display, Parameter 213 must be previously changed from percent to mil-
133
limetre display.
Example: in a retracted state, a table has a height of 610 mm including the
table base and the table top, then the parameter could be set to 610.
Start initialisation: initialisation run started without having to previously pull
out the mains plug of the controller.
211
An initialisation run started can no longer be aborted and must run until it is
finished completely.
Setting the lift height and the type of lift height display.
When setting the value to "0", the lift height will be shown in percent
("xxxP").
If the lift is entered in mm, the lift movement will be shown on the display of
the hand switch.
213
If a default height was set for parameter 133, the cumulative value of the
default height and the lift movement will be shown on the display of the hand
switch.
Note: the lift can be freely selected. Any value can be set, even if this value
does not correspond to the actual lift. In this case, the set lift corresponds to
the complete lift and is scaled accordingly.
Determine the duty cycle: determines the time (in percent/10 minutes), during
which the drives can be moved without interruption.
If you set the duty cycle e.g. to 20 %, the drives can be moved for a maximum
of 2 minutes without interruption. After this, you cannot move the drives until
232
8 minutes have passed.
Note: in the factory setup, the duty cycle is 100 %, i.e. the drives can be moved
for as long as you like without interruption! Despite this 100 %, always
observe the duty cycle for the drives and controllers!
Description
7. Working life
Factory
settings
0
1
0
-
0
100
71