geberit HyTronic Instrucciones De Servicio página 25

Ocultar thumbs Ver también para HyTronic:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 93
The following repair works are described here:
• Removing the cover plate and mounting frame
• Replacing the solenoid valve
• Replacing the regulating screw
• Replacing the lip seal of the flush pipe
• Mounting the mounting frame and cover plate
• Manual flush time setting
Removing the cover plate and
mounting frame
1
2
2
1
3
4
15º
2
5
Remove the battery box (battery-operated flush
control, batteries can be replaced).
1
Disconnect the cables (Step 2 - only for a mains­
operated flush control).
2
Service
EN
2
1
25

Publicidad

Tabla de contenido
loading

Tabla de contenido