Description
Weight of belt unit without activat-
ed charcoal absorber

8. First Use

8.1. Installation on air supply
Note!
The standing time of the activated carbon adsorber in the belt unit and
the quality of the breathing air depend significantly on the pre-clean-
ing of the supplied compressed air. That is why the SATA filter 444
(# 92296) with automatic condensate drain must be mounted upstream.
It filters almost all water and dust particles from the supplied com-
pressed air. If the pressure difference between the pressure gauge
[10-1] and [10-2] is greater than 1 bar, the fine filter cartridge must be
replaced (at least every six months; see SATA filter 400 operating man-
ual).
Note!
To clean the breathing air of oil vapours, the activated carbon filter SATA
filter 464 (# 92247) must be interconnected. The activated carbon filter
must be checked for functionality and maintained on a regular basis. To
avoid a saturation of the activated carbon cartridge, it must be replaced
after 3 months.
The time indicator is included in the scope of supply of every filter and
replacement cartridge!
Note!
To use the half mask, only use an approved compressed air supply tube
(max. 10 m) with quick-action safety couplings (# 49080).
8.2. Assemble the half mask
Note!
When assembling the half mask, do not press against the thin braces in
the exhaling part.
■ Position the head straps and the lower straps.
Operating manual SATA air star C
EN
260 g
107