BFT HYDRA-R Instrucciones De Uso página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
RADIO MENU (RADIO)
-
Add
Allows you to add one key of a radio control device to the receiver memory;
after storage it displays a message showing the receiver number in the
memory location (from 01 to 64).
Add Start button (add start)
associates the required key to Start command
Add 2ch button (add 2ch)
associates the required key to 2nd radio channel
-
Read (read)
Checks one key of a receiver; if stored it displays a message showing
the receiver number in the memory location (from 01 to 64), and the key
number (T1, T2, T3 or T4).
-
Eliminate list (erease 64)
WARNING! Completely removes all memorised radio control devices
from the receiver memory.
Receiver code reading (RX code)
-
This displays the code entered in the receiver.
IMPORTANT NOTE: ATTACH THE ADH ESIVE KEY LABEL TO THE FIRST
MEMORISED TRANSMITTER (MASTER).
In the case of manual programming, the first transmitter assigns the key
code to the receiver; this code is necessary in order to carry out subsequent
cloning of the radio transmitters.
11) RADIO TRANSMITTER CLONING
Clones can be added by means of UNIRADIO, and the only limitation to this
is the maximum number of transmitters the receiver can memorise.
Note: in rolling-code cloning, the level of safety of the code anti-copying
system is very high, and is the same as that of the transmitters memorised
manually in the receivers.
Knowledge of the cloning key code or the reading from the key transmitter
allow the operator to create additional clones by remote control, without
needing further information.
To create replacement clones, you need to have the complete receiver memory
data; therefore, if you plan to carry out replacement cloning operations by
remote control, you need to memorise the contents of the receiver memory
by reading it using UNIRADIO and entering it in the EEdbase database.
When assigning a specific key on an additional clone transmitter to a specific
output channel on a receiver, a predefined procedure is followed.
This procedure can be modified as required if radio transmitter storage is
carried out by means of UNIRADIO, or otherwise it is identical to the procedure
for the first transmitter, the one with the KEY TRANSMITTER LABEL.
The keys on the replacement clone transmitter maintain the same association
with the output channels of the receiver as the replaced transmitter.
Code reading:
In the case where a receiver code is not known, it can be displayed using
the "COD RX" submenu in the Radio menu.
Each time the OK key is pressed, the receiver code is displayed cyclically,
divided in two groups of four characters each and one group of two characters
(ex. COD RX - OK - 1A9C - OK - 22FD - OK - 01). The + and - keys must
be pressed simultaneously to exit the code display.
Having carried out key code reading, you are advised to write it down
on the appropriate card supplied and given to the user (Fig.6).
Note the type of receiver configuration (rolling code or fixed code)
on the card, in order to avoid errors in any subsequent transmitter
cloning operations.
11.1) RADIO-TRANSMITTER CLONING
Rolling-code cloning / Fixed-code cloning
Make reference to the UNIRADIO Instructions and the CLONIX Program-
ming Guide.
11.2) ADVANCED PROGRAMMING: COLLECTIVE RECEIVERS
Make reference to the UNIRADIO Instructions and the CLONIX Program-
ming Guide.
12) CENTRALISED SERIAL CONNECTION
The HYDRA-R control panel allows several automation units to be connected
in a centralised way by means of appropriate serial inputs and outputs (SCS).
This makes it possible to use one single command to open and close all the
automation units connected.
Following the diagram in Fig. 5, proceed to connecting all the HYDRA-R
control panels, exclusively using a telephone-type line.
Should a telephone cable with more than one pair be needed, it is indispen-
sable to use wires from the same pair.
The length of the telephone cable between one appliance and the next must
not exceed 250 m.
At this point, each of the HYDRA-R control panels must be appropriately
configured, by setting a MASTER unit first of all, which will have control over
all the others, to be necessarily set as SLAVE (see logic menu).
INSTALLATION MANUAL
Also set the Zone number (see parameter menu) between 0 and 127.
The zone number allows you to create groups of automation units,
each one answering to the Zone Master unit. Each zone can only be
assigned one Master unit, the Master unit in zone 0 also controls the Slave
units in the other zones.
Loop closing of the serial connection (indicated by a dotted line in Fig.5)
is only needed if you require to check the no. of the connected devices by
means of UNIPRO.
12.1) Programming of centralised installation through Unipro
Connect the UNIPRO programmer to the control unit by means of the UNIDA
accessory (see fig.5).
Make reference to the UNIPRO Instructions for further information.
12.2) Programming of centralised installation through display
The display programmer available in the board allows you to set all the
HYDRA-R control panel functions. Make reference to fig. A and B. Set the
zone number in the PARAMETERS menu, and set the closed loop/open
loop and master/no master values in the LOGICS menu.
13) DIAGNOSTICS AND MONITORING
The display on the HYDRA-R panel shows some useful information, both
during normal operation and in the case of malfunctions.
Diagnostics:
In the case of malfunctions, the display shows a message indicating which
device needs to be checked:
STRT = START input activation
STOP = STOP input activation
PHOT = PHOT input activation
SWO = SWO input activation
SWC = SWC input activation
FLT
= FAULT input activation for checked photocells
In the case where an obstacle is found, the HYDRA-R panel stops the door
and activates a reverse manoeuvre; at the same time the display shows the
"AMP" message.
Monitoring:
During the opening and closing phases, the display shows four digits sepa-
rated by a dot, for example 35. 6 0. The first two digits are constantly updated
during the manoeuvre, and represent the maximum torque reached.
The last two digits represent the torque value set in the parameter menu.
These values allow the torque setting to be corrected.
If the maximum torque value reached during the manoeuvre gets sensibly
close to the value set, malfunctions may occur in the future following wear
or slight door deformation.
It is therefore advisable to check the maximum torque reached (the first
two digits) during some of the manoeuvres carried out in the course of
installation, and if necessary set a value about 15-20 percent points higher
in the parameter menu.
14) STATISTICS
The statistics are managed by the UNIPRO.
In addition to the standard statistics, the following advanced statistics are
available:
- Number of zone operating units (advanced statistics) Address 16: indicates
the number of actuators belonging to the same zone as that of the master
(only updated in the master boards).
- Number of total operating units (advanced statistics) Address 17: indicates
the number of actuators connected (only updated in the master boards).
Make reference to the UNIPRO Instructions for further information.
15) SCRAPPING
Warning: This operation should only be carried out by qualified person-
nel. Materials must be disposed of in conformity with the current regulations.
In case of scrapping, the automation devices do not entail any particular risks
or danger. In case of materials to be recycled, these should be sorted out by
type (electrical components, copper, aluminium, plastic etc.).
16) DISMANTLING
Warning: This operation should only be carried out by qualified person-
nel. When the control unit is disassembled to be reassembled on another
site, proceed as follows:
Disconnect the power supply and the entire electrical installation.
In the case where some of the components cannot be removed or are
damaged, they must be replaced.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.
ENGLISH
15
HYDRA-R - Ver. 05 -

Publicidad

Tabla de contenido
loading

Tabla de contenido