Before performing any work on the blower, remove the connecting cord plug from the machine's socket.
Condition
Battery is not being charged even though
LED on charger glows green
LED on charger flashes red
1)
On STIHL AR battery: accompanied by 4 long beeps
2)
On STIHL AR battery: accompanied by a rapid sequence of beeps lasting several seconds
3)
STIHL recommends an authorized STIHL servicing dealer.
BGA 100
Cause
Battery too hot / too cold
(1 LED on battery glows red)
No electrical contact between charger
and battery
Fault in battery
(4 LEDs on battery flash red for
2)
about 5 seconds
)
Fault in charger
Remedy
Allow battery to cool down / allow battery
to warm up slowly at temperatures of
about 15°C - 20°C (60°F - 70°F)
Operate the charger only in enclosed
and dry rooms at ambient temperatures
between +5°C and +40°C (+ 40°F and
+ 105°F)
Remove the battery and refit it
Take the battery out of the charger and
refit it. Switch on the charger – if the
LEDs continue to flash, the battery has a
malfunction and must be replaced.
Have charger checked by your servicing
3)
dealer