Programming A Heating Profile - HomeMatic IP Easy Connect Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Configuration menu of the radiatorthermostat
temperature offset of ±3.5 °C can be set. If a nominal temperature of
e.g. 20 °C is set but the room presents with only 18 °C, an offset of -2.0
°C needs to be set. An offset temperature of 0.0° is set in the factory
settings. To adjust the offset temperature, please proceed as follows:
Select "Offset" via the plus and minus buttons (E and F) in the
menu.
Confirm with the menu button.
Select the desired offset temperature using the plus or minus
button and confirm with the menu button.
To confirm, the temperature flashes twice and the device changes
back to the standard display.
6.4

Programming a heating profile

In this menu item, you can create a heating profile with six heating and
cooling phases (13 change settings) according to your personal needs.
Select "Prg" using the plus or minus button (E and F) and confirm
with the menu button.
In the menu item "dAy", use the plus and minus buttons to select
single days of the week, all weekdays, the weekend or the entire
week for your heating profile and confirm with the menu button.
Confirm the start time 00:00 pm with the menu button.
Select the desired temperature and start time using the plus or
minus button and confirm with the menu button.
The next time is shown in the display. You can adjust the time via
the plus or minus buttons.
Select the desired temperature for the next time period using the
plus or minus button and confirm with the menu button.
Repeat this procedure until temperatures are stored for the entire
period between 0:00 and 23:59 h.
50