and the activity symbol ( ) are displayed. Wait until the adaption run is
completed. Afterwards, the display returns back to normal.
If the adapter run has been initiated prior to mounting or if
an error message (F1, F2, F3) is displayed, press the menu/
boost button (G) and the motor reverses to the "InS"
position.
5.3
Mounting the window / door contact
5.3.1 Selecting a suitable mounting location
•
Select a window or door for mounting the window / door con-
tact.
•
Fix one part of the window / door contact (magnetic contact (I)
or electronic unit (K) to the moving part (door or window wing),
the other one at the stationary part (frame) of the window or door
(see figure 6).
•
Fasten the window / door contact on the side of the window or
door where the handle is located, in the upper third of the win-
dow/door frame (see figure 6) (for fastening see „5.3.2 Adhesive
strip mounting" on page 46).
•
The magnet contact can be mounted in a horizontal or verti-
cal way, left or right to the electronic unit of the window / door
contact.
The electronic unit and the magnet contact should be
mounted at the same height. You can use a spacer (J) for
the magnet contact.
Installation
45