Control Panel - Quick SBC 300 ADV PLUS FR Manual Del Usuario

Cargador de baterias
Ocultar thumbs Ver también para SBC 300 ADV PLUS FR:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

HALF-POWER MODE
If the supply voltage of the equipment drops under 97 Vac the battery charger will activate the "half power" mode. In
this mode the battery charger can supply, a maximum value half of the maximum nominal output current. In this way
you can reduce the current absorption from the AC supply. This feature is useful when the battery charger is supplied
via a generator or from a berth socket with limited power.
The half power mode can be activated manually by using the RCM1620 remote command.

CONTROL PANEL

The control panel is made-up of three LED, a 7 segment display and a button:
POWER LED, CHARGE PHASE LED (BULK, ABSORPTION, FLOAT) ERROR LED, STATUS display
and ON/STAND-BY button (see fig.4).
FIG.4
ON/STAND-BY BUTTON:
Use this button to put the battery charger in stand-by mode. To activate this mode simply press and release the but-
ton quickly (press and release in less than one second). To take the battery charger out of stand-by mode, press and
release the button quickly again or disconnect the battery charger from the AC power supply and then connect it up
again.
The information supplied by the LEDS are listed as below:
POWER LED
LED COLOUR
DESCRIPTION
OFF
No mains power
Power on
GREEN
Battery charger in stand-by mode
FLASHING
CHARGE PHASE LED (BULK, ABSORPTION, FLOAT)
LED COLOUR
DESCRIPTION
OFF
No output power
RED
BULK PHASE - charge at constant current
ORANGE
ABSORPTION PHASE - charge at constant voltage
GREEN
FLOAT PHASE - float charge
ERROR LED
LED COLOUR
DESCRIPTION
OFF
No problem with manual reset
RED
Problem with manual reset (see error codes)
SBC ADVANCED PLUS MEDIUM - REV005A
OPERATING
GB
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sbc 500 adv plus frSbc 700 adv plus frSbc 650 adv plus fr

Tabla de contenido