SAFETY
IMPORTANT SAFETY INFORMATION
10. For a gate operator utilizing a non-contact sensor:
a. Reference owner's manual regarding placement of non-contact sensor for each type of
application.
b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle
trips the sensor while the gate is still moving.
c. One or more non-contact sensors shall be located where the risk of entrapment or
obstruction exists, such as the perimeter reachable by a moving gate or barrier.
11. For a gate operator utilizing a contact sensor such as an edge sensor:
a. A hard wired contact sensor shall be located and its wiring arranged so the communication
between the sensor and the gate operator is not subject to mechanical damage.
b. A wireless contact sensor such as the one that transmits radio frequency (RF) signals to
the gate operator for entrapment protection functions shall be located where the
transmission of the signals are not obstructed. A wireless contact sensor shall function
under the intended end-use conditions.
c. One or more contact sensors shall be located on the inside and outside leading edge of a
swing gate. Additionally, if the bottom edge of a swing gate is greater than 6" (15 cm)
above the ground at any point in its arc of travel, one or more contact sensors shall be
located on the bottom edge.