USER'S MANUAL. PROMAX-27
4.2.5.1
TV DIGITAL mode
To access this measurement mode from TV mode, press [F1] until you see at the
top of the screen "DIGITAL TV POWER METER" (Figure 23.-).
Measures on the screen are:
PWR:
C/N:
NOISE
FREQUENCY:
FR:
CA:
BW:
At the bottom of the screen you will see next options:
MNS / DIGITAL /
ANALOG [F1]:
IQ [F2]:
SPECTRUM / SCAN [F3]:
LOGGER [F4]:
09/2010
Figure 23.- Digital TV measurement screen.
Power received from the signal. (It appears on numerical and
graphical mode).
Carrier / Noise Ratio.
Noise frequency.
Channel tuned frequency.
Channel and plan channel.
Bandwidth.
Changes among the three TV measurement modes.
It shows a Constellation Diagram for the digital signal in
the whole range of measurement (refer to section
4.2.5.1.1) (for details see appendix B 'Principle of QAM
Modulation. The Constellation Diagram').
It leads to SPECTRUM mode (refer to section 4.2.5.4.2)
/ SCAN mode (refer to section 4.2.5.4.1).
Through this function you can store measurements in
the memory of the instrument for later viewing, printing
or transfer to a PC (refer to section 4.2.5.4.3).