USER'S MANUAL. PROMAX-27
SCAN
Span
Dynamic range
SPECTRUM ANALYSER
Span
Reference level
Analysed band
Detector
Bandwidth
Resolution
Peak detector
Span 100 MHz
Span 50 MHz
Span 30 MHz
Span 15 MHz
Span 5 MHz
Span 1 MHz
Average detector
Span 30 MHz
Span 15 MHz
Span 5 MHz
Span 1 MHz
AUDIO
Demodulation
Output
POWER SUPPLY
Li-Ion battery
Low battery indication
Autonomy
Automatic power-off
Battery charge
Equipment consumption
Mains to charger adapter
ENVIRONMENTAL CONDITIONS
This equipment could be used on the following environmental conditions, on
these conditions the specifications could be also applied:
Altitude
Temperature range
Maximum relative humidity
09/2010
Variable: 10, 30, 100, 300 MHz and full band (from
5 to 862 MHz depending on channel plan).
Variable from 20 to 120 dBuV in 10 dB steps
From 1 to 100 MHz (1, 5, 15, 30, 50, 100 MHz).
Variable from 20 to 120 dBµV in 10 dB steps.
From 5 to 862 MHz.
Peak or average.
200 kHz.
900 kHz.
450 kHz.
280 kHz.
140 kHz.
50 kHz.
10 kHz.
280 kHz.
140 kHz.
50 kHz.
10 kHz.
AM/FM.
Internal loudspeaker.
7.4 V — 4.8 Ah.
Graphic indication on the display:
Approximately 3 hours.
Power-off after approximately 10 minutes of non-
use.
By fast internal charger.
22 W.
Al-103: 100 to 240 V AC / 50-60 Hz / 12 V DC
(EUROPE and other countries).
Up to 2000 metres.
From 5 °C to 40 °C.
80 % (up to 31 °C),
decreasing lineally up to 50 % at 40 °C.
.