MM
FN
32.12
..._32.12
32.11
..._32.11
32.10
..._32.10
32.09
..._32.09
32.08
..._32.08
32.07
..._32.07
32.06
..._32.06
Tab. 2
Assignment of measuring results – Program file
MM Measuring result in mm
FN End of file name (Blank-Holder-Calibration...)
▷ Select the program, whose last 4 file name dig-
its correspond with the noted down measuring
value in step 1. E.g.:
▪ Determined measuring value MM: 31.93 mm
▪ FN calibration file to be selected: Blank-Holder-
Calibration_31.93
▷ Transfer the respective program to the
machine.
▷ Make sure that the machine is set up according
to the necessary data of the program window
OK
and confirm with
.
The milling data are transferred.
▷ After completion of the data transfer, reset the
tool wear for all tools.
Fig. 13
▷ To start the milling process, click on the
button.
The necessary fitting surfaces for applying the
blank holder are milled into the calibration
sleeve.
C A L I B R A T I N G T H E B L A N K H O L D E R
MM
FN
32.05
..._32.05
32.04
..._32.04
32.03
..._32.03
32.02
..._32.02
32.01
..._32.01
32.00
..._32.00
31.99
..._31.99
MM
FN
31.98
..._31.98
31.97
..._31.97
31.96
..._31.96
31.95
..._31.95
31.94
..._31.94
31.93
..._31.93
31.92
..._31.92
The milling procedure is completed after approx.
20 minutes and the operation button [A] starts to
flash. After the milling process, the tool holder
remains in the removal position.
There is no indication in the Ceramill
Motion software that the process has been
completed.
▷ Remove the tool holder from the machine.
▪ Release the lever of the splash guard and pull
off the splash guard toward the front.
▪ Loosen the fastening screw of the tool holder
and pull off the tool holder toward the right.
▷ Clean the locating bore and the surfaces of the
machine.
The calibration milling process is completed.
MM
FN
31.91
..._31.91
31.90
..._31.90
31.89
..._31.89
31.88
..._31.88
E N
25