Elements Of The Complete Installation; Electrical Wiring - Erreka TEMIS Guía Rápida De Instalación Y Programación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TEMIS
Quick Installation Guide
This quick guide is a summary of the complete installation manual. The manual contains safety warnings and
other explanations which must be taken into account. The installation manual can be downloaded by going
WARNING
to the "Downloads" section of Erreka website:
http://www.erreka-automation.com
G
D
C

Electrical Wiring

A.B: 24v DC Motor(2x1mm²)
C: Photocell 2x0.5mm² (max 20m)
D: Control Box (3x1.5mm²)
E: Push Botton 2x0.5mm²(max 25m)
TEMIS It is not applicable to an insecure or lacking rigidity door nor solves the defects due to incorrect installation or mainte-
nance de cient.
Check the following points before starting the installation:
1). Hinges are properly positioned and greased.
2). No obstacles in the moving area and no frictions between two gate leafs or with the ground while moving.
3). "C" value is 139mm.
4). "D" can be measured from the gate easily.
5). "A" = "C" + "D"
6). The value of "B" can be calculated from the value of "A" and the leaves opening angle.
Ex. If "A"=160mm with the leaves opening angle of 100 degrees, then the value of "B" is approximate 190mm.
B
D
A
C
A
TA
F: Key Selector(2x0.5 mm²)
G: Flash Light (2x0.5mm²)
H.I: Electric Lock (2x1mm²)
Assembly levels, inward opening
D Aprox
Please make sure B and A are similar or the same in value that the leaves can be
operated smoothly, also to reduce the burden of the motor.

Elements of the complete installation

H
TC
I
A
140
150
160
170
180
190
200
210
E
0
B
TA
TA: Open Stopper
TC: Closed Stopper
B
140
150 160 170 180 190
200 210
>120°
110°~120°
100°~110°
90°~100°
Open Interior
MSB-026/00
F
1

Hide quick links: