Total Open/Close Programming; Pedestrian Open/Close Programming - Erreka PUMA Guía Rápida De Instalación

Ocultar thumbs Ver también para PUMA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Total opening radio code programming (with RSD receiver only)
If a receiver other than RSD is used,
see the corresponding instructions.
1 Connect
the
electrical
supply and close the gate by keeping
CLOSE pressed down.
2 Select the code in the transmitter.
1 Connect the electrical power supply
and close the gate by keeping CLOSE
pressed down.
2 Place the DIPs as shown in the
figure (DIP2=ON, DIP1=ON).
DL3 lights up to show programming
mode enabled.
3 Press START to start opening.
This is carried out in the same way as total travel
programming, with the following differences:
3 Place the DIPs as shown in the
figure (DIP1=ON, DIP4=ON). DL3
lights up to show programming mode
enabled.
power
R151A
4 Press the button of the required
channel.
DL2
programming is complete.

Total open/close programming

4 Press START to start slowdown
(approx. 50cm before the end of
travel).
R151A
5 Wait for it to come to a stop at the
end of travel.
6 Press START to start closing.
G151A

Pedestrian open/close programming

DL3 remains off.
electrical power supply.
flashes
to
show
Programming is carried out in the
same way, using DIP6 instead of DIP4.
7 Press START to start slowdown
(approx. 50cm before the end of
travel).
G151B
8 Wait for it to come to a stop at the
end of travel.
9 Place DIP1 and DIP2 in OFF. DL3
remains off.
G151D
• DIP1 and DIP3 are used instead of DIP1 and DIP2
• PEDESTRIAN is used instead of START
• In step 5, stop the gate with PEDESTRIAN
5 Place DIP1 and DIP4 in OFF.
6 Disconnect and reconnect the
Pedestrian opening radio
code
G151E