Siemens SITRANS FUS060 Instrucciones De Servicio página 109

Caudalímetros ultrasónicos
Ocultar thumbs Ver también para SITRANS FUS060:
Tabla de contenido

Publicidad

Número de
comando
195
196
197
198
199
200
201
202
205
206
Transmisor FUS060 con HART
Instrucciones de servicio, 08/2015, A5E35189854-AB
Función
Read HART Track1 Layout
Write HART Track1 Layout
Read HART Track2 Layout
Write HART Track2 Layout
Read HART Track3 Layout
Write HART Track3 Layout
Read HART Track4 Layout
Write HART Track4 Layout
Read HART Debug Values Track1
Read HART Debug Values Track2
B.3 Comandos específicos del dispositivo
Parámetro
sensor_track1_length,
sensor_track1_angle,
sensor_track1_displacement
sensor_track1_length,
sensor_track1_angle,
sensor_track1_displacement
sensor_track2_length,
sensor_track2_angle,
sensor_track2_displacement
sensor_track2_length,
sensor_track2_angle,
sensor_track2_displacement
sensor_track3_length,
sensor_track3_angle,
sensor_track3_displacement
sensor_track3_length,
sensor_track3_angle,
sensor_track3_displacement
sensor_track4_length,
sensor_track4_angle,
sensor_track4_displacement
sensor_track4_length,
sensor_track4_angle,
sensor_track4_displacement
phys_debug_gain_up_1,
phys_debug_gain_dw_1,
phys_debug_level_up_1,
phys_debug_level_dw_1,
phys_debug_trigger_up_1,
phys_debug_trigger_dw_1,
phys_debug_rm_tdc_tof_up_1,
phys_debug_rm_tdc_tof_down_1,
phys_debug_delta_tof_1,
phys_debug_meas_error_percent_1
phys_debug_gain_up_2,
phys_debug_gain_dw_2,
phys_debug_level_up_2,
phys_debug_level_dw_2,
phys_debug_trigger_up_2,
phys_debug_trigger_dw_2,
phys_debug_rm_tdc_tof_up_2,
phys_debug_rm_tdc_tof_down_2,
phys_debug_delta_tof_2,
phys_debug_meas_error_percent_2
Comandos HART
Lectura /
Escritura /
Comando
Lectura
Escritura
Lectura
Escritura
Lectura
Escritura
Lectura
Escritura
Lectura
Lectura
107

Publicidad

Tabla de contenido
loading