Data Table - Stiebel Eltron DHC-E 8/10 Manual De Operación E Instalación

Ocultar thumbs Ver también para DHC-E 8/10:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
TECHNICAL DATA
Hot water outlet temperature 60 °C
Cold water inlet temperature
DHC-E 8/10
DHC-E 11 L
DHC-E 12

12.4 Data table

Part number
Phase
Coding plug
Voltage
Frequency
Output power
Amperage
Min. recommended circuit breaker
2 (copper)
Min. recommended wire size
Min. water flow to activate appliance
Protection level according to
Max. inlet water temperature
Nominal water volume
Working pressure max.
Tested to pressure
Weight
Water connections
Part number
Phase
Voltage
Frequency
Output power
Amperage
Min. recommended circuit breaker
2 (copper)
Min. recommended wire size
Protection level according to
Min. water flow to activate unit
Max. inlet water temperature
Nominal water volume
Working pressure max.
Tested to pressure
Weight
Water connections
*
DHC-E 8/10 is a single unit that is switchable at installation via jumper for output at 7.2 kW (Stage 1) or 9.6 kW (Stage 2).
1
Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load.
2
Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
These are our recommendations. Check local codes for compliance if necessary.
www.stiebel-eltron-usa.com
°C 4
10
5.4 kW @ 208 V 1.38
1.55
7.2 kW @ 240 V 1.84
2.06
7.2 kW @ 208 V 1.84
2.06
9.6 kW @ 240 V 2.45
2.75
10.4 kW @ 208 V 2.65
2.98
11.6 kW @ 220 V 2.97
3.33
9 kW @ 208 V 2.30
2.58
12 kW @ 240 V 3.07
3.44
DHC-E 8/10
224201 (U.S. & Canada) / 234450 (Export)
1
1
Position 1
1
V 208
220
Hz 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60
kW 5.4
6.0
A 26
28
1
A 30
30
(DP)
AWG 10
10
gpm / l/min 0.26 / 1
IP 24
°F / °C 131 / 55
gal / l 0.13 / 0.5
psi / bar / MPa 150 / 10 / 1
psi / bar / MPa 300 / 20 / 2
lb / kg 5.9 / 2.7
1/2˝ NPT
DHC-E 11 L
235235 (Not available in North
America)
1
V 208
Hz 50 / 60
kW 10.4
A 50
1
A 50
(DP)
AWG COPPER 8
IP 24
gpm / l/min 0.26 / 1
°F / °C 131 / 55
gal / l 0.13 / 0.5
psi / bar / MPa 150 / 10 / 1
psi / bar / MPa 300 / 20 / 2
lb / kg 5.9 / 2.7
1/2˝ NPT
15
20
25
1.72
1.93
2.21
2.29
2.58
2.95
2.29
2.58
2.95
3.05
3.44
3.93
3.31
3.72
4.26
3.7
4.17
4.76
2.86
3.22
3.68
3.82
4.30
4.91
*
1
1
1
1
1
1
2
2
230
240
208
220
6.6
7.2
7.2
8.1
29
30
35
37
30
30
35
40
10
10
8
8
DHC-E 12
230628 (U.S. & Canada) /
234451 (Export)
1
1
1
220
208
220
50 / 60
50 / 60 50 / 60 50 / 60 50 / 60
11.6
9
10
52.8
44
46
60
50
50
6
8
8
30
35
40
45
2.58
3.09
3.87
5.16
3.44
4.12
5.16
6.87
3.44
4.12
5.16
6.87
4.58
5.50
6.87
9.16
4.72
5.66
7.07
9.43
5.28
6.33
7.91
10.55
4.08
4.90
6.12
8.16
5.44
6.53
8.16
10.88
1
1
2
2
230
240
8.8
9.6
39
40
40
40
8
8
1
1
230
240
11
12
48
50
50
50
8
8
50
55
7.73
15.47
10.31
20.62
10.31
20.62
13.75
25.00
14.15
25.02
15.83
25.02
12.24
24.49
16.32
25.00
DHC-E |
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dhc-e 11 lDhc-e 12Dhc-e 11

Tabla de contenido