LG DLEX8100 Serie Manual De Propietario página 26

Ocultar thumbs Ver también para DLEX8100 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

26
INSTALLATION INSTRUCTIONS
Connecting Electric Dryers (cont.)
USA only
WARNING
Four-wire connection for electric dryers: Direct wire
manufactured home installations, as well as all new
shorter wires into a hook shape.
back of the dryer. Install a UL-listed strain relief into
the power cord through-hole; then thread the power
Power Cord
conductor cable.
and reinstallation of the dryer.
green ground screw to the center screw of the
terminal block. Attach the two hot leads of the power
cable to the outer terminal block screws. Attach the
white neutral wire to the center terminal block screw.
Attach the power cable ground wire to the green
ground screw.
Reinstall the terminal block access cover.
Ground
Screw
Power Cord
Ground Wire
Ground Wire
Terminal
UL-Listed
Strain Relief
.
Neutral
White Wire
moved from
Ground Screw

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Dlgx8101 serieDlgx8101vDlex8100wDlgx8101w

Tabla de contenido