4-wire
connection:
Power Supply Cord
IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do
not permit
the use of 3-wire
connections.
B
c
D
F
E
G
2.
A. 4-wire receptacle" (NEMA type 14-30R)
B. 4-prong plug
C. Ground proI1g
D. Neutral prong
E.Spade terrninal_ with upturned ends
F. %" (t.9 cm; Ut li_te'd strain re'lief
G. Ring terminals
Remove center
silver-colored
terminal
block
screw.
Remove neutral
ground wire from external
ground
conductor
screw. Connect
neutral
ground
wire and the neutral
wire (white or center wire) of power supply
cord
under
center,
silver-colored
terminal
block
screw. Tighten screw.
A
B
C
r
?
3_
Connect
ground
wire !green or bare) of power
supply
cord to external
ground
conductor
screw. Tighten
screw.
B
C
4,
5.
6.
7,
F
D
A. Fxternal ground conductor scre'w
B. O'nter silver-colored
terminal block scre'w
C. Neutral wire' fwhite or center wire)
D. ?4" (1.9 crn) U[ Ibted strain relief
E. Ground wire (gre'en or bare) of power supply cord
t_ Neutral ground wire
Connect
the other wires to outer terminal
block
screws. Tighten
screws.
Tighten
strain relief screws.
Insert tab of terminal
block
cover into slot of dryer rear panel. Secure cover with
hold-
down
screw.
You have completed
your electrical
connections.
Now go to "Venting
Requirements."
D
A. fxternal
ground
conductor
screw
- Dotte'd
line shows
position
of NEUTRAL
ground
wire before
being
moved
to
cente'r silver-colored
ten'ninal
block
screw.
B. C_'nte'r silver-colored
terminal
block screw
C. Neutral
wire" (white
or center
wire')
D. 74" (1.9 cm) UL li_te'd strain
re'lief
E. Neutral
ground
wire"
10