7
Servicing and maintenance
Do not spray the RoMatik XS and the surrounding area (panels,
base) using a water hose, steam-jet air ejector or high-pressure
cleaner.
Caution
Clean the stainless steel coverings with a stainless steel cleaner. We recommend
using Winterhalter C 122 Universal De-Greaser and Stainless Steel Cleaner such as
Winterhalter C 162 Stainless Steel Care in the pressurized spray can.
Clean the control panel with a damp cloth.
Do not use corrosive products, acids, steel wool or wire brushes.
Do not use a scrubbing agent or an abrasive cleaner.
8
Technical Information
Height x Width x Depth
Type of protection
Weight
Admissible noise level under normal operating
conditions
Requirements for the Untreated Water
Electrical Conductivity (at 20° C)
Chlorine
Oxidability
Turbidity
Chloride
Iron
copper
Mangnanese
Sulphate
Langelier Index (corrosiveness of water)
Maximum water inlet temperature
Minimum flow through amount
Minimal water flow pressure
Maximum water inlet pressure
Maximum total hardness (TH)
Power Supply
Voltage
Frequency
Power uptake
Fuse (electronic control panel)
Installation / Connection
Installation
Assembly position standing or lying horizontal on the left side.
The installation site must be frost-resistant so that the water supply systems do not
freeze.
The ventilation grate on the back should not be covered.
Electrical connection
Notes for the electrician:
Connection only to alternating current via correctly installed earthed terminal outlet.
Network voltage and voltage indication on the type plate must agree.
Connection value and required fuses are to be indicated on the type plate.
Network power change (if necessary) only be electrician.
Water connection
Notes for the installer:
Connect RoMatik XS to water and sewer (see connection instructions page 8)
Adhere to the limits of the untreated water (see technical information)
The supply hose may not be shortened or damaged. Old existing hoses may not be
re-used.
For water and sewer connection pursuant to DIN EN 1717: install RoMatik XS WSE
set (20000462)
For dishwashers with pressure boilers: Install compressed air tank between the
RoMatik XS and the dishwasher (RoMatik Expansion Kit 5101127)
Check that the connections are tight.
469 x 142 x 570
mm
IP23
20
kg
55
dB(A)
< 1200
µS/cm
< 0,2
mg/l
< 5
mg/l O2
< 1,0
NTU
< 250
mg/l
< 0,2
mg/l
< 2,0
mg/l
< 0,05
mg/l
< 240
mg/l
< 0
35
°C
300
l/h
1
bar
6
bar
35
° dH
200 - 240
V
50 + 60
Hz
1,5 – 1,7
A
T3.15A
7
English
Capacity
Volume flow prepared water at a water inlet
temperature of 15 °C
Yeild (at 15 °C water inlet temperature)
The yeild is dependent upon the total hardness (°dH) and the conductivity (µS/cm) of the
untreated water. A capillary consisted with these values with colour coding must be
installed on the back of the RoMatik XS at first start up.
Range
Yield
Colour of Capillary
1
55% ±5%
blue
2
40% ±5%
black
3
30% ±5%
white
4
Operation not permitted
Duration of operation under normal operating conditions
Active charcoal filter
140 h
Membrane
until "High cond." displayed on control panel
9
Disposal
Contact your dealer so that the materials in the RoMatik XS can be supplied back to the
material circuit at the earliest possible time.
Position of the connections
Side view
A
Network connections box
B
Water outlet (treated water) G ¾", external thread
C
Water input (untreated water) G ¾", external thread
D
Water outlet (waste water) DN 12
min. 90 l/h
Conductivity
Back view