Warranty; Technical Specifications - Morningstar Essential Serie Manual Del Operador

Ocultar thumbs Ver también para Essential Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.0

WARRANTY

LIMITED WARRANTY Morningstar Solar Controllers and Inverters
The EcoPulse is warrantied to be free from defects in material and workmanship
for a period of TWO (2) years from the date of shipment to the original end user.
Morningstar will, at its option, repair or replace any such defective units.
WARRANTY EXCLUSIONS AND LIMITATIONS:
This warranty does not apply under the following conditions:
♦ Damage by accident, negligence, abuse or improper use
♦ PV or load currents exceeding the ratings of the product
♦ Unauthorized product modification or attempted repair
♦ Damage occurring during shipment
♦ Damage results from acts of nature such as lightning and weather extremes
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN
LIEU OF ALL OTHERS, EXPRESS OR IMPLIED. MORNINGSTAR SPECIFICALLY
DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT
LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. NO MORNINGSTAR DISTRIBUTOR, AGENT OR
EMPLOYEE IS AUTHORIZED TO MAKE ANY MODIFICATION OR EXTENSION
TO THIS WARRANTY.
MORNINGSTAR IS NOT RESPONSIBLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY KIND, INCLUDING BUT NOT LIMITED
TO LOST PROFITS, DOWN-TIME, GOODWILL OR DAMAGE TO EQUIPMENT
OR PROPERTY.
28
Warranty and Policies
6.0
Electrical:
Nominal battery voltage
Battery voltage range
Max. Battery Current
Max. PV open-circuit voltage
Load Current Rating
Self Consumption
Mechanical:
Dimensions:
Weight (lb/kg): Non-metered:
Wire Size Range:
Power Terminals
Maximum Torque
Battery/Temp. Sense
Enclosure
Battery Charging:
4-Stage Charging:
Temperature compensation
Coefficient:
Temperature compensated
set-points:
R17-8/16

TECHNICAL SPECIFICATIONS

EC-10/M
All: 12 or 24 Volts
All: 10-35 Volts
10A
10A
<15mA (non-meter) <20mA (meter)
6.01(W) x 4.14(L) x 2.17(D) in.
153(W) x105(L) x 55(D) mm
0.75 / 0.34
Metered:
0.90 / 0.40
2.5 - 16 mm
0.25 - 1.0 mm
Bulk, Absorption, Float, Equalize
-30mV / ºC / 12 Volt
Absorption, Float, Equalize,
High Voltage Disconnect (HVD)
EcoPulse Operator's Manual
EC-20/M
EC-30/M
20A
30A
All: 60 Volts
20A
30A
1.1 / 0.48
1.2 / 0.54
/ #14 - 6 AWG
2
35 in-lb
/ #24 - 16 AWG
2
IP20, Type 1
29

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ecopulse ec-10Ecopulse ec-10mEcopulse ec-20Ecopulse ec-20mEcopulse ec-30Ecopulse ec-30m

Tabla de contenido