SKF LAGD 60 Instrucciones De Uso página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
LAGD 125
mm
inch
A
117
4.606
øB
54
2.125
C
11
0.433
LAGD 60/125
LAGD 60
mm
inch
86
3.386
54
2.125
11
0.433
2. Installation
1. Write the installation date on the unit with a
water-resistant pen.
2. Remove the end cap of the lubricator.
3. Turn the dial with a coin to activate the lubricator.
4. Clean the area around the lubrication point.
5. Remove the previous unit or old grease fitting.
6. Attach the new unit hand tight.
7. We recommend to check the general condition of
the bearing and the position of the
lubricator piston every quarter of the dispense
time.
For example: each week at the 1 month setting or
every 3 months at the 12 month setting.
When the unit is installed on a new application:
1. Make sure that the grease in the SYSTEM 24 is
suitable.
2. Fill the supply lines and the bearing with grease.
3. Make sure the grease is compatible.
4. Make sure the ambient temperature is between
-20 °C and +60 °C. If the ambient
temperature is constantly above +40 °C do not
select a dispense rate of more than 6
months for optimum performance.
5. Make sure the unit supplies grease to the bearing,
or component to be lubricated.
6. Install the unit no more than 300 mm (grease) or
1 500 mm (oil) from the bearing.
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lagd 125

Tabla de contenido