Product Disposal; What To Do If - Nice ERA XL Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27

Product disposal

This product is an integral part of the automation and
therefore must be disposed together with the latter.
As in installation, also at the end of product lifetime, the
disassembly and scrapping operations must be performed
by qualified personnel.
This product comprises various types of materials: some
may be recycled others must be disposed of. Seek infor-
mation on the recycling and disposal systems envisaged
by the local regulations in your area for this product cat-
egory.
- some parts of the product may contain pollutant or
hazardous substances which, if disposed of into the envi-
ronment, may cause serious damage to the environment
or physical health.
As indicated by the symbol alongside, disposal
of this product in domestic waste is strictly pro-
hibited. Separate the waste into categories for
disposal, according to the methods envisaged
by current legislation in your area, or return the
product to the retailer when purchasing a new version.
- Local legislation may envisage serious fines in the
event of abusive disposal of this product.
Switch off the drive for cleaning and maintenance. After these checks, if the motor still does not move, contact a
specialist technician or the Nice Assistance Service.
Fault
Drive does not run
Mains connection is OK.
Drive does not run.
Mains connection is OK.
Drive does not run.
Drive does not run in the specified
direction.
End positions are incorrect.
End positions are incorrect.
Shutter runs diagonally.
Shutter does not run smoothly.

What to do if...

(troubleshooting guide)
Cause
Remedy
No voltage
Check the mains connection.
Coil temperature limiter has
Disconnect; the coil temperature limiter switches
switched off.
on again automatically after cooling down.
ERA XLH motor limit switch
Turn the crank handle approx. ¼ of a turn back;
disabled.
this re-enables the motor's limit switch.
Incorrect connection.
Swap over the black and brown wires.
End position exceeded in
Readjust the limit switches.
emergency operation.
Winding shaft axially shifted
Repair the system and secure against axial shift-
and limit switch crown does
ing.
not rotate with it.
Fixings or slats are damaged.
Repair the system.
Shutter is scraping against an
Repair the system.
object.
Guide rail damaged.
English – 7