Problem: charge indicator [1] is continuously on.
Reason: battery is charging.
Possible solutions: this is a normal operating condition.
Problem: charge indicator [1] is blinking.
Reason: battery is trickle-charging.
Possible solutions: this is a normal operating condition when battery is fully charged.
Problem: charge indicator [1] is off.
Reason: no power from solar panels.
Possible solutions:
• This is a normal condition during night time when the solar panel doesn't receive any
sunlight
• When it happens during day-time, carefully check all connections and make sure they
are all secured tightly.
9.

Technical Specification

rated voltage
load current (max.)
overvoltage protection
over-charge protection
over-discharge protection
temperature compensation
no load loss
max. cable section
operating temperature
solar panel input voltage
dimensions
weight
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use of this
device.
For more info concerning this product and the latest version of this user manual,
please visit our website www.velleman.eu.
The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman
nv. All worldwide rights reserved. No part of this manual may be copied, reproduced,
translated or reduced to any electronic medium or otherwise without the prior written
consent of the copyright holder.
25/11/2010
SOL30UC2
12Vdc / 24Vdc (auto-detection)
20Vdc / 40Vdc
13.7V/27.4V (default value, can be reset)
10.5V/21V (default value, can be reset)
-3mv/°C/cell
max.20mA
-25°C - 55°C
12V system max.20V/24V system max.40V
162x110x50mm
6
30A
6mm²
371g
©Velleman nv