Machine Control Panel

Key Switch (See Figure 3, Item "A")
The key switch turns "ON" the power to the control
panel. "O" is "OFF" and "I" is "ON".
Forward Reverse Switch (See Figure 3, Item "B")
On Traverse ("L") Model Only - The forward/reverse
switch turns the traverse motor "on" forward and if the
brush motors are in the down position, activates the
brush motors/solution control module. There is a two
second delay for the pad motor to stop after releasing
the switch. Either the right or the left switch can be
used. Use either switch in conjunction with the white
reverse switch to reverse the traverse motor.
"S" Model - These switches activate brush motors
and solution/control module if brush motors are in the
down position.
Battery Meter (See Figure 3, Item "C")
The battery meter indicates the relative charge on the
battery pack. Do not continue to run the machine
when the needle is in the "red" area. This will shorten
the life of the battery pack.
Brush Pressure Meter (See Figure 3, Item "D")
The pad pressure meter indicates the relative amount
of pressure the pad is putting on the floor. To maxi-
mize run time on a battery charge, keep the needle
towards the center of the green area.
Reverse Switch (See Figure 3, Item "E")
On Traverse Model Only
The reverse switch, when used in conjunction with one
of the forward/reverse switches, causes the machine to
reverse directions. The reverse speed is 70% of the
forward speed.
Hour Meter (Not Illustrated) (Option)
The hour meter indicates the number of hours the
machine has operated. It runs only when the brush
motor is on.
K
B
C
Page
-10-
E
A
N
G
F G H I J
Figure 3
Clarke
®
Operator's Manual (EN) - Encore S2426 / L2426 / S2426 OBC / L2426 OBC
Circuit Breakers (See Fig 3, Items "F", "G", "H", "I" & "J")
The circuit breaker reset buttons are located on the
rear cover. The breakers are located as follows:
Item F - Actuator Head (5 amp)
Item G - Vacuum Motor (30 amp)
Item H& I - Brush Motor (40 amp)
Item J - Traverse Motor (25 amp) (L2426 only)
If a circuit breaker trips, determine which motor is not
operating and turn the key switch "OFF". Wait five
minutes and push the reset button back in. Turn the
key switch "ON" and try again. An authorized service
person should be contacted if the breaker trips again.
Control Handles (See Figure 3, Item "K")
The control handles are located at the rear of the
machine. They are used to guide the machine.
Solution Control Knob (See Figure 3, Item "L")
The solution control knob regulates the flow of chemi-
cal solution to the floor. To increase the flow, turn
knob clockwise. To decrease the flow, turn counter
clockwise. Full counter clockwise is OFF and full
clockwise is ON.
Traverse Speed Knob (See Figure 3, Item "M")
To increase speed, turn knob clockwise.
Brush Motor Switch (See Figure 3, Item "N")
To activate brush motor, push brush position switch to
down position. Brush Motor and solution flow will
activate when the traverse buttons are pushed. To
shut brush motor off, hold brush position switch in up
position until actuator stops.
Vacuum Motor Switch (See Figures 4 & 5, pg. 11)
To activate vacuum motor, lower squeegee handle.
Handle has two positions. Lowest position is
operating position and the middle position is transport
to clear vacuum hose.
K
L
H
M
K
B