Dometic Waeco SinePower MSI2312T Instrucciones De Montaje página 37

Ocultar thumbs Ver también para Waeco SinePower MSI2312T:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 77
SinePower
NOTE
I
Note when connecting devices with an electrical drive (such as
power drills and refrigerators), that they often require more power
than is indicated on the type plate.
The inverter has various protective mechanisms.
 Overvoltage shutdown: The inverter shuts itself off when the voltage ex-
ceeds the cut-off value. It restarts when the voltage returns to the restart
value.
 Undervoltage shutdown: The inverter shuts itself off when the voltage
sinks below the cut-off value. It restarts when the voltage rises to the re-
start value.
 Excess temperature shutdown: The inverter switches off when the tem-
perature inside the device or the temperature on the cooling element ex-
ceeds a cut-off value. It restarts when the voltage rises to the restart
value.
 Overloading and short circuit shutdown: The LED on the inverter indi-
cates an operating fault (constant red light) when an excess load is con-
nected or a short circuit has occurred. The fuse in the device must be
pressed in again by hand after it is triggered by excess current.
 Incorrect polarity protection: The incorrect polarity protection prevents
the wrong polarity when connecting the inverter.
NOTE
I
The individual values are found in the chapter chapter "Technical
data" on page 50.
The inverters have a 230 Vw socket and a connection terminal for perma-
nent connection.
Due to the voltage synchronisation with the AC input voltage, the inverter is
suitable for operating sensitive consumers which react to an irregular voltage
supply.
The device can also be configured with a PC via an RS 232 interface and us-
ing the DIP switches on the device.
The inverter can be switched to an energy-saving mode to prevent the con-
nected battery from discharging too quickly.
Parallel operation allows up to three inverters (of the same model) to run at
the same time.