SinePower
9.8
Connecting the remote control (accessory)
NOTICE! Beware of damage
A
Only plug in the connection to the remote control in the LCM port.
The device can be damaged by connecting it incorrectly. Ensure
that the remote control and inverter are supplied with the same in-
put voltage.
➤ Connect the remote control (accessory) to the LCM port (fig. 5 13,
page 4).
10

Using the inverter

10.1
Switching on the inverter
➤ Set the main switch (fig. 5 3, page 4) of the inverter to the "ON" position.
Set the On/Off switch to "OFF" to switch off.
➤ The inverter performs a self-test.
During the self-test, the built-in speaker emits tones and the LED flashes.
✓ After the self-test is completed successfully, the LED lights up green
(fig. 5 2, page 4).
10.2

Status indications

The LED (fig. 5 2, page 4) shows the operating condition of the inverter.
Display
Green, constantly lit
Green, slow flash
Orange, quick flash
Orange, slow flash
Red, double flash
Red, quick flash
Red, slow flash
Red, constantly lit
Red, slow flash + double flash
EN
Input voltage
Normal mode
Energy-saving mode
Input voltage too high
Input voltage too low
Inverter overheated
Overvoltage
Undervoltage
Overload
Fan fault