2. The fault code will be displayed. Use the up and down arrows to scroll through the
faults. Resolve the issue with the action listed in Description of Fault Codes chart and
the Fault screen will disappear. To remove a tamper fault, select CLEAR.
IMPORTANT: See the Description of Fault Codes for more details regarding a fault and
resolution actions. All faults, except a tamper, will automatically be cleared when the issue
has been resolved. An event will be recorded in the event log indicating the date and time
that the event occurred and was resolved.
NOTE: A tamper fault will not be automatically cleared. After the device has been
inspected, checked for damage, and the cover closed, the fault will need to be cleared.
See Clearing a Fault. This process was designed to create awareness of the tamper
with the master user and require verification that the problem has been resolved.

CLEARING A FAULT

To clear any fault other than a tamper fault, correct the condition at the sensor. For
example: replace the battery, relocate to an area with a better signal, etc.
To Clear a Tamper Fault:
IMPORTANT: Before clearing a tamper fault, be sure that the issue has been resolved.
Only the master user can clear tamper faults.
1. When the Fault Code screen is displayed; select CLEAR.
2. Use the keypad to enter the master code.
3. Select OK.

DESCRIPTION OF FAULT CODES

NOTE: See the Troubleshooting Guide for more detailed information.
DESCRIPTION OF FAULT CODES
Fault Code
Fault Display
Power
Primary Power
Lost Base
DevPower
Primary Power Lost
Device #
BaseLowBatt
Base
Low Battery
DevLowBatt
Low Battery
Device #
WeakSig
Weak Signal
Device #
Unsecured
Unsecured
Device #
NoCheckIn
No Check In
Device #
Description
Action
No power to
Check power supply
Base Unit
No battery power
Change battery, reset
in device
Base Unit
Plug in power supply
battery low
to recharge battery
Device battery
Change battery, reset
low
Transmission signal
Check for interference;
from device is weak
move device
Device has
Check for intrusion;
been tripped
re-secure device
Device check-in
Check for interference;
messages have not
move device
been received
DESCRIPTION OF FAULT CODES cont.
Fault Code
Fault Display
Tamper
Tamper
BaseBadBatt
Bad Battery
Base
CellRadio
Cell Radio
Fault
Receiver
Receiver Fault
Device #
NetControl
Base Network
Control
NOTE: The battery will take up to 24 hours to charge completely. To avoid draining
the battery, do not use an outlet that is controlled by a wall switch. The battery is
designed to be a back-up source of power for up to 8 hours. If the monitoring service
has been activated, the Base Unit will send a low battery message to the monitoring
servce approximately 1 hour before the battery is drained. If power is not restored
within that remaining hour, the Base Unit will disarm and shut down.
IMPORTANT: After power has been restored, the Base Unit will not be armed.
FEATURES & OPTIONS

System Settings

The systems settings menu allows for changes in user codes, wireless devices, automatic
arming, delays and account information.

• Wireless Device Maintenance

• Change Master Code
• User Code Maintenance
• Set Console Devices
• Set Delay/Instant
WIRELESS DEVICE MAINTENANCE
After the initial setup, a device such as a sensor or Key Chain Remote can be added,
edited or removed.
• Adding or Replacing a Device
• Editing a Device
• Removing a Device
1. Start at the main screen.
2. Select MENU or press MAIN MENU on the keypad.
3. Using the keypad, enter the master code.
10
Description
Action
Device has been
Close device or
opened or damaged
replace if damaged
Base Unit battery has
Needs to be repaired
dropped below the
at D
WALT authorized
E
voltage limit
service center
Cellular radio
Move Base Unit to
signal is lost
a location where
or scrambled
CELL light is solid;
call Customer Service
if problem persists
2-way transmission
Call customer service
of device is lost
to test system for issues
Base RF processor
Internal check; will clear
communications
itself; call Customer Service
if problem persists
• Clear Settings
• Auto Arm ON/OFF
• Auto Arm Time Set
• Review Account