INSTALLATION
only intended for qualified personnel
Before installing the hood, carefully read the chapter 'SA-
FETY INSTRUCTIONS AND WARNINGS' .
TECHNICAL FEATURES
The technical specifications are exhibited on the labels located inside
the hood.
POSITIONING
The minimum distance between the highest part of the cooking
equipment and the lowest part of the hood is indicated in the in-
stallation instructions.
Generally, when the hood is placed over gas cookers, the distance must
be at least 65 cm (25.6''). However, according to an interpretation of
standard EN60335-2-31 dated 11-07-2002 of TC61 (sub-clause 7.12.1
meeting 15 agenda item 10.11), the minimum distance between the
cooker and lower part of the hood can be reduced to the quota re-
ported in the installation instructions.
Should the instructions for the gas cooker specify a greater distance,
this must be taken into consideration.
Do not install the hood outdoors and do not expose it to outdoor envi-
ronment (rain, wind, etc.).
ELECTRICAL CONNECTION
(only intended for qualified personnel)
Disconnect the equipment from electrical mains power
supply before carrying out any operations on the hood.
Ensure that the wires inside the hood are not disconnected
or cut:
in the event of damage, contact your nearest Servicing Depart-
ment.
Refer to qualified personnel for electrical connections.
Connection must be carried out in compliance with the provisions
of law in force.
Before connecting the hood to the electrical mains power supply,
check that:
• voltage supply corresponds with what is reported on the data plate
located inside the hood;
• the electrical system is compliant and can withstand the load (see
the technical specifications located inside the hood);
• the power supply plug and cable do not come into contact with
temperatures exceeding 70 °C;
• the power supply system is effectively and properly connected to
earth in compliance with regulations in force;
• the socket used to connect the hood is within reach.
In case of:
• devices fitted with cables without a plug: the type of plug to use is a
''standardised'' one. The wires must be connected as follows: yellow-
green for earthing, blue for neutral and brown for the phase. The
plug must be connected to an adequate safety socket.
• fixed equipment not provided with a power supply cable and plug,
or any other device that ensures disconnection from the electrical
mains, with an opening gap of the contacts that enables total discon-
nection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power
supply in compliance with installation regulations.
The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with
the safety regulations.
FUMES DISCHARGE
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this version, air passes through zeolite-carbon
filters and the E.ION ionising system to be puri-
fied and recycled in the environment. Make sure
the zeolite-carbon filters are installed in the hood,
otherwise, apply them as indicated in the assembly
instructions.
ASSEMBLY INSTRUCTIONS
only intended for personnel qualified
The hood can be installed in various configurations.
The generic assembly steps apply to all installations; for
each case, follow the specific steps provided for the re-
quired installation.
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct
fumes and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all
vapours and odours. By means of the Timer function, it is possible to set
auto switch-off function which will allow the hood to turn off automati-
cally after 15 minutes of operation.
AIR QUALITY
Air quality is displayed by the colour of the leaf.
Green = excellent quality.
Yellow = pollutant agents found.
The higher the number of pollutant agents, the
darker the yellow
colour.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity
consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
(*)Note: 4th speed not included on SPRING and LYBRA models.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal filters must be cleaned every 30 hours of operation.
The zeolite-carbon filters must be reactivated every 18 months and re-
placed every 3 years.
For further details see the "MAINTENANCE" chap.