Rated voltage
Rated power
Circuit breaker
Position of electrical connection
180
7
90
3
3
1/2"
Set the height of the toilet based on the position of the drain
according to the technical drawing of the toilet.

Pre-installation

DANGER
Risk of fatal electric shock
> Disconnect electrical components from the power supply
before the installation.
> Check that all components are de-energised.
> Prevent the power supply from being switched on
accidentally.
> Ensure that there is no damage to the power supply cable.
> Lay a permanent power supply line which must be on a
separate circuit:
> Observe the position of the electrical connection
> Leave at least 800 mm (31½ ") of feed cable exposed
> Install circuit breaker
> The product itself does not have electrical leakage
protection function, it must be installed in circuit where
there is leakage protection device installed.
> Means for disconnection must be incorporated in the
fixed wiring in accordance with the wiring rules and
having a contact separation in all poles that provide full
disconnection under overvoltage category III conditions.
10
57313_Mounting_SeWa_Starckf_EU/19.08.1
220 – 240 V 50 – 60 Hz
1080 W
I
= 16 A
N
1/8"
90
1/2"
RCD
Protection degree
Protection class
22
Connecting the cable
> Remove the insulation from the wires approximately
10 mm (⅜ ").
> Connect the 3 wires to the terminal block. Observe the
L, N and PE conductors.
> Confirm that the grounding wire is 10 mm (⅜ ") longer
than the L and N wire.
I
= 30 mA
N
IP X4
I