For The User - Bosch Tronic 3000 C Pro Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

16 | Troubleshooting
6.2

For the User

Symptom
Little or no water flows.
Cold water only -neon light
off.
Cold water only -neon light
on.
Water flow rate too low, or
temperature too high.
Table 7
6 720 647 088 (2011/09)
Cause
The water supply is turned off.
The flow is not high enough to
activate.
The water flow rate is too high.
The flow rate is correct.
The inlet water temperature has
dropped.
The hot tap is not fully open
What do do
Turn on the main supply fully at the stop valve.
Open the inlet service valve fully.
Adjust the flow rate with hot water outlet
service valve.
Adjust the temperature dial on the front of the
cover.
Adjust the flow rate with hot water outlet
service valve.
Adjust the stop/ball valve so that water is at the
right temperature with the tap fully open.
Always turn the hot tap fully on.
US

Hide quick links:

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Us 12mwihb

Tabla de contenido