4.6

Starting up

4.6.1 Checking for leaks and purging air

▶ Verify all circuit breakers supplying power to the water
heater are turned off.
▶ Open all hot water taps supplied by the water heater and
inspect all water connections for leaks.
▶ With all hot water taps still open, inspect each tap to ensure
all air in the lines has been purged out.
▶ With the air purged and taps still flowing, turn on all circuit
breakers supplying the water heater.
▶ Close all hot water taps and proceed to the next section.
6.50
6.00
5.50
5.00
4.50
4.00
3.50
3.00
2.50
95
100
Fig. 8
These figures are based on an inlet water temperature of 55 °F
and a supply voltage of 240 volts. If the inlet water temperature
is lower than 55 °F, or if the supply voltage is less than 240
volts, then the flow rate for the shown temperatures will be
reduced shown in Fig. 8. If a higher outlet water temperature is
desired, then reduce the flow rate and/or supply the unit with
240 volts.
Tronic 5000C
Outlet temperature vs Maximum flow rate setting
(based on incoming water temperature of 55ºF)
105
110
Outlet temperature (ºF)

4.6.2 Adjusting the temperature dial

▶ The temperature adjustment is made using the dial on the
bottom edge of the unit. The adjustment is between
approximately 95 °F and 131 °F. Turning the dial clockwise
increases the temperature setting as indicated by the
marking on the unit.

4.6.3 OPTIONAL: Adjusting the flow

▶ Confirm hot water temperature setting is acceptable at a
sink.
▶ Open fully both inlet and outlet shut-off valves at the
heater, then:
▶ Turn on fully the highest flowing hot water fixture (e.g.,
bathtub) served by the water heater.
▶ If the water temperature is not hot enough, adjust the outlet
shut-off valve until the temperature is acceptable. Use
Fig. 8 below for reference if you know your maximum flow.
115
120
Before leaving the site, the installer should
demonstrate the unit to the user and give
them this guide.
Installation | 13
131
125
130
6720647022-03.1V
6 720 647 022 (2014/06)