POS.
DESCRIPTION
1
Water Tank
2
Tank mounting
3
Tank mounting
4
Tank mounting
5
Tank mounting
6
Red plastic washer
7
White plastic washer
8
Blue plastic washer
9
Relief / non return valve
10
Hose clamp
11
Pipe
12
Electric element gasket
13A
Electric element
1200W 220V
13B
Electric element
500W 220V
13C
Electric element
1200W 110V
13D
Electric element
600W 110V
14
Double thermostat
15
Plastic spacing bar
16
Cap
17
Screw
18
Nuts
19
Ground cable terminal
20
Washer
BOILER BX16 - REV006A
CODE
MLB160000000
MBFPGX700300
MBFPGX720300
MBFPNX395300
• shut down power supply.
MBFPNX400300
• Remove the protection cover (16) in order to reach the
PECRBLRS0000
thermostat (14).
PECRBLBNC000
• Adjust the thermostat knob with a screwdriver (fi g. 4)
PECRBLBL0000
adjust the thermostat to its max temperature.
MNVALS12S68P
• Push the reset button on the double thermostat (fi g. 4).
PBF25100W000
• Re-adjust the thermostat knob with a screwdriver (fi g.
PVTBGM5NT030
4) and turn it until the required temperature.
• Replace on the protection cover (16).
PGGRES000000
• Switch on power supply.
EVR122200000
EVR052200000
EVR121100000
MAINTENANCE
EVR061100000
EVT15S000000
We recommend checking the magnesium anode (A) every
PBTE25H6FMF0
12 months.
PCCPLT600000
Replace the anode if its size has been reduced signifi cantly.
MBV0306MXCE0
This simple and preventive maintenance will ensure a long
MBD04MXEN000
life of the equipment.
EJCY04000000
MBR04X000000
F
Periodically check the joints of the water pipe installation;
check the tightness of the securing screws and replace
them in case they are worn or corroded.
Also periodically check the electrical system working order.
MAINTENANCE
WARNING: Quick
®
nautic water heaters are provid-
ed with a double thermostat with manual reset that
shuts down power supply in case of an excessive
water temperature.
If it happens, follow the instructions below:
WARNING: if the high temperature safety system
switches on repeatedly, call Quick
During wintertime, when the water heater is not
in use it should be drained using the lever of the
valve (9). This is to avoid serious damage caused by
freezing.