Power requirements Part 2
Power cables
•
The usable cable thickness and length depend on the power situation on
the job site.
•
General rule: The shorter and thicker the cable, the better.
•
Recommendations cable thickness:
- for countries with 230 volts nominal voltage: 3 x 1.5 mm
- for countries with 110 volts / 120 volts nominal voltage: 12 gauge
cable (3 x 2.5 mm
•
Use only cables appropriate for this application. Check the
cables regularly for damage.
•
Outdoors, use only extension cables approved and marked for
this purpose.
Start-up isoweld
The induction welding tool is delivered ready for operation ex-works.
3
The country-specific regulations must be observed.
)
2
®
3000
After opening the container, the body of the unit
can be carefully lifted out. Then the handle of the
tool (see overview) is removed from the transport
box and carefully inserted into the tool.
2
1
5
4
1. Use fixing screw to secure the
push-fit connection.
2. Adjust the handle to an ergonomic
working height. For this purpose,
release the clamping lever at the
upright and adjust the height.
Re-tighten the clamping lever.
3. Connect the tool to a suitable
power source.
- the cable should not be too long
- suitable conductor cross section
- unroll extension cable
Ensure that the connection is
correctly made.
4. Operate mains switch to turn unit
on.
5. The display shows the input
screen.
2
17