• A minimum of 10 cm from the inductor should be maintained at all
times during operation, with the exception of handles, etc.
Safety instructions
General safety instructions – Part 2
• Always switch the tool off and remove the mains connector during breaks or
maintenance work. Do not leave the tool unattended.
• When carrying out maintenance and service work, the power connection to
the tool must be disconnected.
• Regularly check the tool for damage, and that it is functioning properly. Use
the tool only if it is functioning properly.
• Repairs may only be carried out by a specialist.
• Only use system components from SFS or approved by SFS. Do not use any
accessories or spare parts from other manufacturers without approval by SFS.
• The functionality of this system is guaranteed when original fastener, stress
plate, spare parts from SFS are used, and the unit is operated in accordance
with the operating instructions.
• Do not use or wear isoweld
or ladder.
• Always inspect isoweld
• isoweld
stress plates must be stored dry, covered and protected from
®
sunlight to prevent soiling and damage caused by UV radiation. isoweld
stress plates must not be exposed to the elements for more than 24 hours.
WARNING!
• Using an isoweld
may result in a strap or connection breaking while in use and the machine
may fall causing personal injury.
Special safety instructions
• When working on roofs with a
slope of between 0 and 10° a
guard rail must be fixed at the
edge of the roof.
• When the roof slope is more than
10° special safety devices must be
employed.
• When the working height is more
than 10 ft. (3 m) above ground,
appropriate fall prevention
measures must be employed
(see below).
• Fall prevention measures for work lasting less than 2 working days. In the case
of work that takes longer, proceed as described above (see below).
>5 m
8
®
Backpack on an unstable support, steep incline
Backpack straps and connection points before use.
®
Backpack tool with damaged straps or connection points
®
®
>3 m
>5 m