Kehrsaugmaschine
AKS 88|BM 180
STARTING
It is advisable to start the machine with central and side brushes all lifted up and not in movement
Release the brake if the machine is in braking position Part. 3 Fig. 7
Turn the key clockwise Part. 10 Fig. 8.
MOVING
Push forward the lever Part. 4 Fig. 8.
Gradually press the pedal Part. 2 Fig. 7. To reach the maximum speed push on the pedal until it stops.
Release the pedal to arrest the moving.
REVERSE
Take back the lever Part. 4 Fig. 8.
Gradually press the pedal Part. 2 Fig. 7. To reach the maximum speed push on the pedal until it stops.
Release the pedal to arrest the reverse.
EMERGENCY STOP
In case of emergency remove your foot from the forward pedal Part. 3 Fig. 7.
With the same foot press the brake pedal Part. 2 Fig. 7.
Turn the ignition key to the OFF position Part. 10 Fig. 8.
START POSITION
The machine is in the start position when the following functions are set up:
Central brush down; lever Part. 1 Fig. 9
Central brush in rotation, switch Part. 11 Fig. 8 in position ON
Suction turned ON, double fan running, switch Part. 3 Fig. 8
Side brushes in start up position, switches Part. 5 Fig. 8 and Part. 9 Fig. 8 in position ON.
CHAP. 11 – PROPER USE AND ADVICE
WARNING: Before starting remove cords, wires in plastic or metal, electric wires, sticks, rags from the floor. This material must be
eliminated because it causes damage to the brushes and to the anti-dust gaskets.
Air suction is fundamental to prevent dust spread in the working area. The suction system must always be "ON" except in the two following
cases:
1 -
TRACES OF WATER ON THE SURFACE TO BE CLEANED
2 -
DURING THE FILTER SHAKING OPERATION WITH THE ENGINE RUNNING
In the event of points 1 and 2, block the air suction turning the switch OFF, Part. 3 Fig. 8.
Be careful when going over rails or guides etc. They are the main source of damage for anti-dust gaskets. Go over them very carefully.
The side brush must only be used to clean borders, angles, corners etc. The brush must be lifted and turned OFF just after the use to avoid
spread of dust in the air.
In case of bulky objects or very light debris (leaves, packets of cigarettes etc) lift the front flap by pressing the flap pedal with the left foot
heel. Part. 4 Fig. 7.
EMPTING THE DUST CONTAINER
Stop the central brush rotation and lift the brush moving the lever forward Part. 14 Fig. 8.
Raise the dust container by moving bit by bit the lever Part. 1 Fig. 10 to the backward position and by pressing at the same time the
buttons Part. 12 e Part. 13 Fig. 8.