Specifications
Display: 3-1/2–digit LCD (1999 maximum count)
Polarity: Automatic
Sampling Rate: 2.5 per second
Overload Protections:
Volts: 600 VAC RMS and 600 VDC
Amps:
A: 10 A/250 V F fuse, interrupting rating 200 A, 1/4" x 1-1/4"
mA: 0.5 A/250 V F fuse, interrupting rating 1500 A, 5 mm x 20 mm
Overvoltage Protection Categories:
VΩ Terminal: Category III, 300 VAC and 300 VDC; Category II, 600 VAC and 600 VDC
mA Terminal: Category III, 250 VAC and 250 VDC
A Terminal: Category III, 250 VAC and 250 VDC
Operating Conditions: 5 °C to 40 °C (41 °F to 104 °F) , 0 to 80% Relative Humidity
Elevation: 2000 m (6500') maximum
Indoor use only
Storage Conditions: –10 °C to 60 °C (14 °F to 140 °F), 0 to 70% relative humidity
Remove battery
Pollution Degree: 2
Battery: 9-Volt battery (NEDA 1604, JIS 006P or IEC 6F22)