20 | English
When vacuuming materials with or without an exposition limit
3
value ≥ 1 mg/m
(according to dust category L), it is possible
to vacuum directly into the container.
Note: When using a paper filter bag, the automatic filter
cleaning (AFC) (see "Deactivating the AFC", page 21) must,
and when using a fleece filter bag, should be shut off.
The vacuum cleaner contains materials
WARNING
that are hazardous to one's health.
Have the emptying and maintenance, incl. the disposal of
dust-collection containers, carried out only by specialists.
Appropriate protective equipment is required. Do not op-
erate the vacuum cleaner without the complete filter sys-
tem. Otherwise there is danger to your own health.
Inserting a Disposal Bag
– Unlock the latches 13 and remove the vacuum lid 12.
– Insert the disposal bag 25 into the container 1 with the fill-
ing opening toward the front.
– Pull the filling opening over the connection flange into the
recess of the connection flange.
– Make sure that the disposal bag 25 faces completely
against the interior sides of the container 1.
– Fold the rest of the disposal bag 25 over the edge of the
container 1.
– Reattach the vacuum lid 12 again and lock the latches 13.
Removing and Closing the Disposal Bag
– Unlock the latches 13 and remove the vacuum lid 12.
– Pull the full disposal bag 25 toward the rear off of the con-
nection flange.
– Carefully remove the disposal bag 25 out of the vacuum
cleaner without damaging it.
When doing this, pay attention that the disposal bag does
not get caught or ripped open against the connection
flange or other sharp objects.
– Pull the cover off of the adhesive strip, close the disposal
bag and tape it shut.
Afterwards, tie off the disposal bag 25 below the filling
opening with the pulled off cover of the adhesive strip.
Replacing/Inserting the Dust Bag (Accessory)
– Unlock the latches 13 and remove the vacuum lid 12.
– Pull off the full dust bag from the connection flange toward
the rear. Close the opening of the dust bag by folding down
the lid. Remove the closed dust bag from the vacuum
cleaner.
– Work the new dust bag over the connection flange of the
vacuum cleaner. Make sure that the dust bag faces com-
pletely against the interior sides of the container 1 over its
full length.
– Reattach the vacuum lid 12 again and lock the latches 13.
Inserting the Rubber Lip (Wet Vacuuming)
(see figure E)
Note: The requirements for the ingress degree (dust category
M) have only been proven for dry vacuuming.
– Carefully pry the brush inserts 29 out of the floor nozzle 30
using a suitable tool.
– Insert the rubber lips 28 into the floor nozzle 30.
1 609 92A 2N3 | (12.12.16)
Note: The structured side of the rubber lips must face out-
ward.
Attaching an L-Boxx (see figure F)
For transport of the vacuum cleaner and for place-saving stor-
age of VAC accessories and/or power tools, an L-Boxx can be
mounted on the vacuum cleaner lid.
– Mount the L-Boxx onto the retainers 11.
 Do not carry the vacuum cleaner by the carrying handle
of the mounted L-Boxx. The vacuum cleaner is too heavy
for the carrying handle of the L-Boxx. Danger of injury and
causing damage.
Operation

Starting Operation

 Observe correct mains voltage! The voltage of the pow-
er source must agree with the voltage specified on the
nameplate of the vacuum cleaner. Equipment marked
with 230 V can also be operated with 220 V.
 Please inform yourself about the valid regula-
tions/laws for your country concerning the handling of
materials that are hazardous to one's health.
The vacuum cleaner is suitable for vacuuming and extracting
the following materials:
– Dusts with an exposition limit value ≥ 0.1 mg/m
The vacuum cleaner may generally not be used in rooms
where the danger of an explosion exists.
To save energy, only switch the vacuum cleaner on when us-
ing it.
To ensure optimal vacuuming performance, always complete-
ly unwind the vacuum hose 24 from the vacuum cleaner lid
12.

Dry Vacuuming

Vacuuming of deposited dusts
– Set the airflow regulator 6 to the hose diameter being
used.
– To switch the vacuum cleaner on, set the mode
selector switch 7 to the "vacuuming" symbol.
– To switch the vacuum cleaner off, set the mode
selector switch 7 to the "Off" symbol.
The vacuum cleaner is fitted with airflow monitoring. In the
"vacuuming" mode, the airflow monitoring is fixed on a value of
20 m/s, irrespective of the setting of the airflow regulator 6.
If the value falls below this, e.g. due to accumulated dirt in the
suction hose, a full dust bag or a clogged flat-fold filter, an audi-
ble alarm signal will sound.In this case, switch off the vacuum
cleaner and check it as stated in the section "Correction of Mal-
functions".
3
Bosch Power Tools