Comunello Automation QUAD - 230V - 2M Instrucciones De Uso Y De Instalacion página 33

Tabla de contenido

Publicidad

programming, by pressing SELECT twice (obtaining fast flashing of LED L7
instead of once) and then press SET.
Repeat the procedure if you wish to restore the previous configuration.
8.3 MENÙ ESTESO 2
La centrale è fornita dal costruttore con la possibilità di selezione diretta
solamente delle funzioni del menu principale.
Se si desidera abilitare le funzioni descritte nel Menù esteso 2, procedere
nel seguente modo:
• Posizionarsi sul lampeggio del LED LEV;
• Premere 2 volte SET;
Il led inizierà a lampeggiare (lampeggio alternato dell LED LEV
);
Si entra così nel settaggio delle seguenti funzioni:
L1
SOFT STOP
ON
L2
SOFT START
OFF
L3
STOP / PASS BUTTON
ON
L4
DEADMAN
ON
L5
FOLLOW ME
ON
L6
FLASH. PAUSE
ON
L7
ALWAYS CLOSE
ON
LEV
MENU
This will allow 30 seconds for the selection of Extended Menu 2 functions
using the SELECT and SET buttons. After a further 30 seconds, the control
unit returns to the main menu.
8.3.1 LED L1 - SOFT STOP:
The control unit is supplied by the manufacturer with the Soft Stop function
disabled. To enable the function, proceed as follows:
• Ensure that you have enabled the Extended Menu 2 (highlighted by the
flashing 1 1 0 1 1 0 of the LED LEV);
• Position yourself with the SELECT button on the flashing light of LED L1;
• Press the SET button;
• At the same time, LED L1 will turn on in a fixed manner and the
programming will be completed.
In this way, the control unit will reduce the speed to zero gradually (within
2 seconds) at the end of the door stroke, when an intermediate STOP
command or an inversion command is sent.
Repeat the operation if you want to restore the previous configuration.
Notes:
- do not confuse the SOFT STOP with SLOWDOWN; the first is enabled at
the end of its stroke, while the second is enabled before it;
- Soft-stop does not act when a limit stop is intercepted and when the Stop
button is enabled; it acts in the event of inversion of the movement and
when a photocell is activated.
8.3.2. LED L2 - SOFT START:
The control unit is supplied by factory with the Soft Start function disabled.
With this function enabled at the beginning of the movement the speed
gradually increase from the minimum to the value set by the "SPEED"
trimmer during the first 2 seconds of operation.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 2 (as shown by the
alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L2;
• LED L2 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
NOTE: when the Soft Start function is enabled, the control unit automatically
disables the Starting Torque function, while if Soft Start is disabled then
Starting Torque is automatically enabled.
8.3.3. LED L3 - STOP / PEDESTRIAN BUTTON.:
By default, input 8 in CN2 is used as a STOP (N.C.); to convert the input to
Pedestrian Button (N.O), proceed as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
• LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
NOTE:STOP Input (N.C.) is factory bridged. To wire the pushbutton,
remove the jumper from the input.
8.3.4 LED L4 - LED L4 - HOLD-TO-RUN:
The control unit allows setting the "Deadman" operation. To enable this
operation mode, proceed as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the
• By the key SELECT, position yourself on the blinking LED L2;
• Press the SET key;
• LED L2 becomes steady on and programming will be completed.
In this way, using both the remote controls and the Buttons for the actuation
OFF
of the shutter, you will get the following operation: it is necessary to keep
ON
the desired command constantly activated (button pressed constantly) to
OFF
obtain the movement of the door of the shutter. The release of the control
will cause the stroke to stop immediately.
OFF
Repeat the procedure if you wish to restore the previous configuration.
OFF
8.3.5. LED L5 - FOLLOW ME:
OFF
The control unit allows the "Follow me" function to be configured;
OFF
programmable only if a Pause Time has already been set (see section
7.1.6.), this function reduces the Pause Time to 5 seconds after freeing
2 FLASHING LIGHTS
the DS1 photocell, meaning the gate re-closes 5 seconds after transit of
the user
ATTENTION: this command is programmable only if a Pause Time has
already been programmed.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 2 (as shown by the
• By the key SELECT, position yourself on the blinking LED L5;
• Press the SET key;
• LED L5 will turn on in a fixed manner and the programming will be
Repeat the procedure if you wish to restore the previous configuration.
8.3.6 LED L6 - FLASHING LIGHT DURING PAUSE TIME:
The control unit is factory set with Flashing Light during Pause Time
disabled. If you wish to enable this function, proceed as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the
• By the key SELECT, position yourself on the blinking LED L6;
• Press the SET key;
• LED L6 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.3.7 LED L7 - ALWAYS CLOSE:
The control unit provides the facility to set "Always Close" operation: this
function, which is programmable only if a Pause Time has already been
programmed (see section 7.1.6.), is activated after a power failure; if
the gate open condition is confirmed a closing movement is started
automatically, preceded by 5 seconds of pre-flashing. If you wish to enable
the function, proceed as follows:
ATTENTION: this command is programmable only if a Pause Time has
already been set.
To enable this operation mode, proceed as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the
• By the key SELECT, position yourself on the blinking LED L7;
• Press the SET key;
• LED L7 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
alternate flashing 1 1 0 1 1 0 of LEV LED);
alternate flashing 1 1 0 1 1 0 of LEV LED);
alternate flashing 1 1 0 1 1 0 of LEV LED);
completed.
alternate flashing 1 1 0 1 1 0 of LEV LED);
alternate flashing 1 1 0 1 1 0 of LEV LED);
COMUNELLO ®Copyright 2019 - All rights reserved
33

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Quad 230v 2m

Tabla de contenido