Morningstar SUNSAVER Serie Manual Del Operador página 5

Controladores de sistemas fotovoltaicos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE: The SunSaver load connection is not a required
connection. Additionally, loads that exceed the load rating
of the SunSaver can be connected directly to the battery.
7. The controller is shipped with a jumper installed. This sets the
controller for charging SEALED batteries. If a FLOODED battery
is being used, simply remove the jumper to optimize the battery
charging for a flooded battery. If the jumper is connected again,
the charging will return to the setpoints for a sealed battery.
8. For most effective surge protection, it is recommended that the
battery negative conductor be properly grounded.
M
SOMMAIRE DES CARACTERISTIQUES
Tension du Systéme
Tension Maximale du
Capteur Photovoltaïque
Intensité Nominale du
Courant Photovoltaïque
Charge Nominale
Courant de Court-Circuit
Maximal du Capteur
PV=photovoltaïque
Pour Toutes les Versions:
Points de:
MLI Batterie Étanche .................................... 14,1 (28,2 pour 24V)
MLI Batterie Humide..................................... 14,4 (28,8 pour 24V)
Point de Déclenchement Basse
Tension ...................................................... 11,5 (23.0 pour 24V)
Point de Réenclenchement Basse
Tension ...................................................... 12,6 (25.2 pour 24V)
Tension de Fonctionnement Minimale .......... 6V
Masse ............................................................... Négative
Montage en Parallèle ..................................... Oui
Consommation ................................................ 8 à 10 mA
D'U
ANUEL
(V)
(V)
(A)
(A)
(A)
TILLISATION
SS-6
SS-10
12
12
25
25
6.5
10
6
10
8.1
12.5
5
SS-20
24 Volt
12
24
25
44
20
n/a
20
n/a
25
n/a

Publicidad

Tabla de contenido
loading

Tabla de contenido