System Volts
Maximum PV Volts
Rated PV Input
Rated Load
Maximum Array
Short Circuit Current
PV=photovoltaic
For All Versions:
Setpoints:
Sealed PWM .......................................... 14.1V (28.2V for 24V)
Flooded PWM ........................................ 14.4V (28.8V for 24V)
LVD ......................................................... 11.5V (23.0V for 24V)
LVD Reconnect ....................................... 12.6V (25.2V for 24V)
Minimum Voltage to Operate ................ 6V
Ground ...................................................... Negative
Parallel Capability .................................... Yes
Self-consumption ..................................... 8 to 10 mA
25% Current Overload Capability .......... 5 minutes
Reverse Current Protection at Night .... Yes
Ambient Temp Range .............................. –40 to 60°C
Temp Compensation ................................ –28 mV/°C (–56 mV/°C for 24V)
Tropicalization .......................................... Epoxy encapsulation
Battery Charging ..................................... Constant voltage series PWM
Green LED ................................................ Charging
Red LED .................................................... Load disconnect
Weight ...................................................... 0.23 kg / 8 oz.
Max. Wire Size ......................................... 5.2 mm², #10 AWG
O
PERATOR
SPECIFICATION SUMMARY
(V)
(V)
(A)
(A)
(A)
'
M
S
ANUAL
SS-6
SS-10
12
12
25
25
6.5
10
6
10
8.1
12.5
2
SS-20
24 Volt
12
24
25
44
20
n/a
20
n/a
25
n/a