For Your Safety; Description; Intended Use; Carrying Method - Dräger Oxy K 30 HW Instrucciones De Uso

Ocultar thumbs Ver también para Oxy K 30 HW:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23

For Your Safety

Strictly follow the Instructions for Use
Any use of the oxygen self-rescuer requires full understanding and strict
observation of these instructions.
The oxygen self-rescuer is only to be used for purposes specified here.
Maintenance
The oxygen self-rescuer must be inspected and serviced regularly by
trained service personnel.
Repair and general overhaul of the oxygen self-rescuer may only be carried
out by trained service personnel.
We recommend that a service contract be obtained with Dräger Safety and
that all repairs also be carried out by them.
Only authentic Dräger spare parts may be used for maintenance.
Accessories
Only use accessories mentioned in the order list.
Disposal
Used or opened units have to be disposed professionally, since the
reaction between the air humidity and the used chemical can generate an
aggressive base.

Description

Oxy K 30 HW/HS/HS KD is an oxygen self-rescuer, independent of the
ambient air, with a closed to-and-fro breathing system which uses
chemically-bound oxygen and a fire escape hood.
Oxy K 30 HW/HS/HS KD has a nominal duration of 30 minutes (at the
breathing rate of 35 L/min according to DIN 58 639). The operating period
can be significantly extended depending on the users breathing rate.
The Oxy K-Series of oxygen self rescue devices conform to DIN 58 639
and meet the requirements of EC Council Directive PPE (89/686/EC).

Intended Use

Oxy K 30 HW/HS/HS KD is intended for emergency escape from areas
filled with smoke or toxic gases or lacking oxygen.
Restriction:
Oxy K 30 HW/HS/HS KD is only suitable for use in the temperature
classes T1, T2, T3 and T4.
CAUTION:
Due to the possible presence of oxygen in the hood, the user must
avoid direct contact to flames or sparks when carrying the
Oxy K 30 HW/HS/HS KD. The presence of oxygen in the hood
increases fire hazards, which can result in serious injuries or even
death.
If the emergency exit is completely blocked by flames and sparks,
direct contact can to a large extent be avoided by covering the hood
with ones own body.

Carrying Method

Oxy K 30 HS/HS KD
Everyday carried on the shoulder.
Other methods are possible, such as
transport in a vehicle
on the chest with additional chest strap
in an emergency on the chest.
10
Before Placing the Oxygen Self-Rescuer into
Service
Before first use, the entrepreneur/user must ensure the following (see
European Directive 89/656/EEC):
the Personal Protective Equipment must fit perfectly,
the Personal Protection Equipment must be compatible with other
types of protective equipment worn at the same time (e.g. protection
jacket),
the Personal Protective Equipment must be suitable for existing work-
place conditions,
the Personal Protective Equipment must take account of ergonomic
requirements and the worker's state of health.
Oxy K 30 HS/HS KD
The Oxy K 30 HS/HS KD has to be weighed upon being delivered.
When weighing the oxygen self-rescuer, detach the harness.
The measured weight has to be compared with the weight on the metal
plate.
CAUTION:
If the weight is more than 6 grams off the listed weight, the oxygen
self-rescuer has to be discarded.
Before placing the oxygen self-rescuer
into service, the customer has to mark
the oxygen self-rescuer with the dates of
the inspection intervals on the metal
plate. The metal plate is on the backside
of the oxygen self-rescuer.
The use of letter punches is not
allowed. Dräger recommends
engraving or etching.
There are six open fields on the
metal plate.
st
1
field –date of delivery– fill in month and year
(e.g. 07/03)
nd
st
2
field –1
Inspection– fill in date of delivery plus three years
(e.g. 07/06)
rd
nd
3
field –2
Inspection– fill in date of delivery plus five years
(e.g. 07/08)
th
rd
4
field –3
Inspection– fill in date of delivery plus seven years
(e.g. 07/10)
th
th
5
field –4
Inspection– fill in date of delivery plus nine years
(e.g. 07/12)
th
6
field –End of Lifetime– fill in end of lifetime of the oxygen self-
rescuer. The end of lifetime depends on use and storage (see "Service
Life Record" on page 15)
Furthermore you will find on the metal plate the following dates filled in by
the manufacturer:
date of manufacturing
serial number
part number
weight
CE Marking
Product Standard
Designation
st
Date of
Date of delivery
1
. Inspection
manufact.
Serial Number
nd
2
. Inspection
Fill out
Part Number
by
customer
rd
3
. Inspection
Weight
th
End of Lifetime
4
. Inspection
CE 0158
DIN 58639

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Oxy k 30 hsOxy k 30 hs kd

Tabla de contenido