CAUTION! This adjustment strongly affects the safety of the gate automation.
Make sure that the gate thrust complies with statutory regulations.
If the gate speed is changed the amperometric sensor must be calibrated accordingly.
The power transformer has a Faston connector (VMOT) which can be used to set the motor speed. The
VMOT Faston is factory set on the 30V secondary circuit (i.e. high speed).
To reduce the speed set the VMOT Faston on 20V.
The 24V secondary circuit of the transformer is reserved for powering VAUX accessories.
By setting the VMOT Faston on 20V the motor speed is also reduced during the slowdown cycles.
The control unit has a series of LED's to provide diagnostic information on the status of all the functions:
POWER LED
Blinks to signal the unit is powered
STOP LED
ON when the STOP button is pressed
PHOT LED
OFF when the photocells are not aligned or obstructed
OPN LED
ON when the OPEN button is pressed
CLS LED
ON when the CLOSE button is pressed
PP LED
ON when the PP (Step-by-step) button is pressed
SWO LED
OFF when the SWO open travel limit switch trips
SWC LED
OFF when the SWC close travel limit switch trips
SWO-R LED
OFF when the SWO-R open slowdown travel limit switch trips
SWC-R LED
OFF when the SWC-R close slowdown travel limit switch trips
Before any action the control unit runs a check-up on its correct operation. If any error is found the motor
is stopped and the Power LED blinks rapidly to signal there is a fault.
The control unit is fitted with a built-in radio module for receiving remote controls both with fixed codes
and variable codes (see dip-switch 8 functions), with a frequency of 433.92MHz.
For a transmitter to be used, the module first has to self-learn its code. The memorise procedure is
illustrated below, the module can memorise up to 64 different codes.
Memorising a new transmitter by activating the P.P. function
- Press the PGM button once for 1sec and the Power LED will start blinking at 1 sec intervals.
- Press the transmitter button within 10 sec to memorise with the P.P. (Step-by-step) function
To exit the programming procedure wait 10 sec or press the PGM button for 1 sec, the Power LED will
return to normal blinking at 3 sec intervals.
Cancelling all transmitters from the memory
- Keep the PGM button pressed for 15 sec, the Power LED will start blinking rapidly and when it goes out
the memory has been erased.
- Release the PGM button, the memory has been cancelled and the Power LED will return to normal
blinking at 3 sec intervals.
N.B.:
The transmitters are stored on an EPROM (U6) memory board that can be removed and installed in a new
control unit in case of breakdown.
For safety reasons, transmitters cannot be memorised during the open/close cycles of the motor.
When entering the memorise transmitter procedure, if the Power LED gives a prolonged blink and then
goes out, this signals that the receiver memory is full and no other transmitters can be memorised or that
the transmitter is not compatible.
Motor speed adjustment
Configuration with built-in receiver (only "RI" versions)
Diagnostic LED's
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cp.k3-riCp.k4-reCp.k4-ri

Tabla de contenido