Delta T Off; Delta T On - Dal Zotto TECLA Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

STBY FUNCTION SET AT OFF DEFAULT SETTING
If the Stby function is not active (OFF), if the stove reaches the set room temperature, it will go to minimum, modulating and displaying
modulate. When the room temperature is below the setting, it will start to work again at the set power and displaying work.

DELTA T OFF

The function allows for the setting of DELTA T OFF.
CONTROLS PROCEDURE
Š Press key 6 and set power will appear.
Š Press key 2 several times until settings is displayed.
Š Press key 6.
Š Press key 2 until DELTA T OFF is shown and use key 6 to con rm.
Š Use keys 4-5 to set the DELTA T OFF (OFF - 0.5 - 5.5°C)
Š Press key 1 several times to con rm and exit the menu.

DELTA T ON

The function allows for the setting of DELTA T ON.
CONTROLS PROCEDURE
Š Press key 6 and set power will appear
Š Press key 2 several times until settings is displayed.
Š Press key 6.
Š Press key 2 until DELTA T ON is shown and use key 6 to con rm.
Š Use keys 4-5 to set the DELTA T ON (OFF - 0.5 - 5.5°C)
Š Press key 1 several times to con rm and exit the menu.
STAND BY WITH ADDITIONAL THERMOSTAT
The STBY function is used if immediate stove switch-o is required when the set temperature has been reached.
By default, the STBY function is always set to OFF (indicator
STBY FUNCTION SET TO OFF FACTORY SETTING
Should the STBY function not be active (OFF), if the stove reaches the room temperature set on the additional thermostat (contact open), it
will go to minimum, modulating and displaying
(contact closed), it will start to work again at the set power displaying
STBY FUNCTION SET TO ON
When the STBY function is activated (ON), the stove, upon reaching the set room temperature and exceeding it by 2°C, will switch o after a
pre-set default delay, displaying STAND BY.
When the room temperature is below the setting on the additional thermostat, it will start to work again at the set power displaying
CONTROLS PROCEDURE
Press key 6 and SET CLOCK will appear.
Š
Press key 2 several times to reach SET USER.
Š
Con rm using key 6.
Š
Press key 2 several times to reach STAND BY.
Š
Š
Using key 4 or 5, select ON.
Press key 6 to con rm and key 1 to return to the previous menus up to the initial status.
Š
The STAND BY function is active.
50
on).
. When the room temperature is below the setting on the additional thermostat
MODULATE
.
WORK
ENGLISH
WORK

Publicidad

Tabla de contenido
loading

Tabla de contenido