Page 6
ENGLISH
Section 2.
General Description
2.1
Introduction
This manual contains information for the proper
installation, operation, and maintenance of Jandy Pro
Series VS Plus HP pumps. Procedures in this manual
must be followed exactly. To obtain additional copies
of this manual, contact Zodiac Pool Systems, Inc. at
1.800.822.7933 or visit www.zodiacpoolsystems.com.
2.2
Description
The VS Plus HP is a variable-speed pump that can
run from 600-3450 RPM. When connected to the
JEP-R controller, up to eight (8) speed settings may
be programmed and recalled. This allows you to select
the most appropriate speed for your application. Even
more versatile programming is possible when you use
an AquaLink® RS, AquaLink PDA, or AquaLink Z4
controller.
The pump is driven by a variable speed ECM
(Electronically Commutated Motor) directly attached
to the pump impeller which forces water flow. The rate
variability allows for optimal flow during various pump
cycles. As a result, the energy efficiency of the pump is
maximized which means cost savings to the pool owner
while also helping to save the environment.
2.3
Preparation
1. Check the carton for damage. Open the carton
and check for concealed damage, such as cracks,
dents, or a bent base. If you find damage, contact
the shipper or the distributor where the pump was
purchased.
2. Inspect the contents of the carton and verify that
all parts are included. See "Figure 1. Carton
Contents".
ITEM
DESCRIPTION
01
VSPHP27 Pump
02
Installation and Operation Manual
03
Large Drawstring Bag
04
Universal Union Nut
05
Tailpiece
06
O-Ring
For VSPHP27JEP Models only
07
Small Drawstring Bag
08
User Interface Universal Control
09
Backplate Universal Control
10
DIP Switch Label
11
Cable Label
12
4 Conductor Cable
13
Terminal Bar 4 Pin
14
Manilla Envelope
15
Mounting Screw
- For a complete list of replacement parts
please see section 7.1
Figure 1.
Carton Contents
Jandy
Pro Series VS PlusHP Pumps
®
Section 3.
3.1
3.1.1 Pump Location
1. Zodiac Pool Systems, Inc. recommends installing
NOTE The pump is NSF-certified for priming at heights
2. If the pump is located below water level, isolation
A check valve can interfere with the proper opera-
tion of certain Suction Vacuum Release System
(SVRS) products. To avoid possible entrapment
hazard, serious injury, or death, make sure to re-
view the operation/owners manual of your particu-
lar SVRS product before installing the check valve.
NOTE When the pool equipment is located below the
3. Install the pump such that any disconnecting means
QTY
09
1
1
1
10
2
2
2
11
12
1
13
1
1
07
1
1
1
1
1
6
|
Installation & Operation Manual
Installation
Plumbing
the pump no more than one (1) foot (30 cm) above
water level. The pump should not be installed
more than five (5) feet above the water level of
the pool. It is recommended that a check valve be
installed when pump is installed more than 3 feet
above water level.
up to 10 ft. above the water level. However, to
achieve better self-priming, install the pump as
close as possible to the water level of the pool.
valves must be installed on both the suction
and return lines to prevent pool water back flow
during routine or required servicing.
WARNING
pool surface a leak can result in large scale
water loss or flooding. Zodiac Pool Systems,
Inc., cannot be responsible for such water
loss, flooding or damage caused by either
occurrence.
and/or junction boxes for power connection are
within sight of the pump and at least five (5) feet
horizontally from the edge of the pool and/or spa.