Programming An Intercom Call From The Indoor Station To The Smartphone - Urmet 1083/58 Manual De Usuario

Ocultar thumbs Ver también para 1083/58:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
Max
no. of
Type of
internal
cable
stations
per riser
column
2Voice /
HVV05-F
1 mm
128
2
(AWG17)
Cat5 /
telephone
wire pair with
64
Ø 0.6 mm
(AWG22)
Wire, 1 mm
2
32
(AWG17)
(*) Any excess devices must be powered off local
power supplies ref. 1083/24
It is possible, however, to calculate the exact
number of Call Forwarding Devices (without
power supply) that can be arranged within the
system, knowing the type and the number of
indoor stations that you wish to use:
1. In the case of a system with 2Voice cable
or HVV05-F cable 1 mm
wire, 1 mm
(AWG17)
2
CFSAmax = [127 – PI1 – (2*PI2) – CF] / 8
2. In the case of a system with Cat5 cable or
telephone wire pair with Ø 0.6 mm (AWG22)
CFSAmax = [127 – PI1 – (2*PI2) – CF] / 30
Where:
CFSA: is the result that expresses the
maximum number (rounded down) of
Call Forwarding Devices without power
supply that can be powered off the
system BUS.
PI1:
number of indoor stations (video door
phones/door phones) mod. Miro or
video door phones mod. Aiko/Folio
present in the system.
PI2:
number of indoor stations (video door
phones mod. Modo or PABX interfaces)
present in the system.
CF:
Number of Call Forwarding Devices
present in the system.
6. LINE IN, LINE OUT terminals: connection to
the system bus.
18
No. of video
Max no. of Call
door phones/
Forwarding
door phones
Devices
mod. Miro
powerable
with Call
from the
Forwarding
system BUS (*)
Device
≤12
all
13÷19
11
20÷23
10
24÷27
9
28÷31
8
32÷35
7
36÷39
6
40÷43
5
44÷47
4
48÷51
3
52÷55
2
56÷59
1
60÷63
0
≤18
3
19÷32
2
≤12
all
13÷16
11
(AWG17) or single
2
7. Jumper Z: line termination setting.
Line termination must be activated on a
device connected at the end of a line without
a new section restarting from the LINE OUT
terminals.
Termination on
(DEFAULT)
Termination off
8. Dip switch CODE: they defi ne the number of
the apartment in the column:
no. 1: do not move, it should remain set
to OFF (if set to ON and then back to OFF, it
will return the column address to its default
value);
no. 2 to 8: they defi ne the apartment number
in the column
For no. 2 to 8 dip-switch settings, refer
to the System 2Voice manual.
O N
=
2.4.
PROGRAMMING AN
INTERCOM CALL FROM
THE INDOOR STATION
TO THE SMARTPHONE
After ensuring that the Call Forwarding Device is
confi gured correctly, go to the indoor station to be
programmed as the caller.
According to the model of indoor station used,
there are 2 different ways of carrying out
programming (check which method is used in
the instruction manual supplied with the indoor
station):
A) Programming with handset on-hook (Mod.
Miro).
1. Make a call from the outdoor station to the
indoor station.
2. On your smartphone, answer the call and
leave the conversation open.
3. On the indoor station:
a. press and hold the button
than 5 seconds; programming start is
confi rmed by the yellow LED starting to
fl ash at a slow rate;
b. now press the key to be programmed
(e.g.
) for at least 3 seconds until a
confi rmation tone is heard.
O N
=
for more
DS1083-078

Publicidad

Tabla de contenido
loading

Tabla de contenido