RIB KIT KING PLUS Manual Del Usuario página 30

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G G
B B
- A -
CONNEXIONS
J1
SEC.TRANSF.
Secondary transformer connector
J2
AERIAL
Radio antenna
COM
Common contact unit
PHOT.1 NC
Photocell contact (NC)
LSO
Stop opening limit switch M1 (NC)
LSC
Stop closing limit switch M1 (NC)
LSO
Stop opening limit switch contact M2 (NC)
LSC
Stop closing limit switch contact M2 (NC)
STOP
Stop button contact (NC)
OPEN
Opening button contact (NO)
CLOSE
Closing button contact (NO)
K BUTT.
Single pulse contact (NO)
A*A
Accessory power supply at 24Vac
SIGNAL
Gate open light 12Vdc
BUZZER
Wiring acoustic warning (12Vdc max 200 mA)
LOCK
Electric lock connection (Max 15W 12V)
J3
U - MOTOR 2
MOTOR 2 COMMON CONNECTION UNIT
V-W - MOTOR 2
MOTOR 2 INVERTER AND CAPACITOR
CONNECTION
U - MOTOR 1
MOTOR 1 COMMON CONNECTION UNIT
V-W - MOTOR 1
MOTOR 1 INVERTER AND CAPACITOR
CONNECTION
BLINKER (max 40W )
J4
L1 - N
Power supply 230Vac 50/60Hz (on request
120V/60Hz)
J5
PRI.TRANSF.
Connector for transformer primary connection
J6
HEATER SUPPLY
Connector for heater supply board (Optional -
DO NOT TOUCH THE GUARD! )
J7
ENCODER
Terminal board for Encoder M1 and M2
connection
S-M1
Encoder M1 signal
+ M1
Encoder M1 power positive sign
GND
Encoder M1 and M2 power negative sign
+ M2
Encoder M2 power positive sign
S-M2
Encoder M2 signal
J8
EXP.
Connector for EXPANDER board
J9
RADIO
Connector for 24Vac radio receiver
J10
HEATER
Connector for heater board control
J11
DO NOT TOUCH THE JUMPER !
I F I T I S R E M O V E D T H E O P E R AT O R
DOESN'T MOVE !
NOTE: IF THE ELECTRIC LIMIT SWITCHES ARE NOT USED, THERE IS
NO NEED TO BYPASS THEM OUT WITH A JUMPER. THEY CAN
BE BYPASSED IF JUMPER S3 IS OPEN.

Publicidad

Tabla de contenido
loading

Tabla de contenido