Stop Button; Technical Specifications - RIB KIT KING PLUS Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

If the encoder operates the closing or the opening and than gives a
reverse command, the gate stops and reverses Its movement for 1
second. The buzzer buzzes to alarm for 5 minutes and the blinker
blinks for 1 minute.
During or after the 5 minutes, when the buzzer alarms, you can make the
gate work again just pressing the operating button you want.
PHOTOCELL 1 (COM-PHOT 1)
If DIP 6 is OFF => The gate does not open if there is an obstacle within
the photocells range of action. During operation,
photocells work both when the gate opens (by starting
the opening movement again after half a second time),
and when it closes (by starting the reverse movement
after one second time).
If DIP 6 is ON => If there is an obstacle within the photocells range of
action when the gate is closed and its opening is
commanded, the gate opens (during Its opening,
photocells do not work). Photocells work only while the
gate Is closing (by starting Its reverse motion after one
second, even if they are still engaged).
N.B.: Every six months make sure to check that photocells are not
out of order

STOP BUTTON

The STOP button stops the gate during any operation.
If you push it when the gate is totally open (or partly open, by using the
pedestrian command), this button temporary excludes the automatic
closing (if selected by DIP3). It Is than necessary to operate another
command to make the gate close again.
The automatic closing function Is enabled again with the following
operating cycle (if selected by DIP3).
BLINKER
N.B.: This electric board can supply power ONLY TO BLINKERS
WITH BLINKING CIRCUIT (ACG7059), with max. 40W lamps.
PRE-BLINKING FUNCTION:
DIP 8 - OFF => the motor, the blinker and the buzzer start at the same
time.
DIP 8 - ON => the blinker and the buzzer start 3 seconds before the
motor.
BUZZER (Optional)
Wiring acoustic warning (12Vdc max 200 mA).
The buzzer emits an intermittent sound signal during opening and
closing cycles. When safety devices are operated (alarm), the
intermittence frequency of this sound signal increases.
WARNING LIGHT - GATE OPEN (COM-SIGNAL):
Its function Is to signal when the gate Is open, partly open or not totally
closed anyway. It turns off only when the gate is totally closed.
This warning signal is not enabled during the programming procedures.
N.B.: If you overuse the push button panels or the lamps, the
control board logic system may be compromised, resulting
into a possible operation block.
T
ECHNICAL SPECIFICATIONS
- Moisture
- Power supply voltage
- Frequency
- Max. power consumption of the card
- Transient power mains drops
- Max. capacity of the warning light - gate open 3 W (corresponding to 1
- Max. load at blinker output
- Available current for photocells and accessories 0,4 A ±15% 24Vac
- Available current for the radio connector
- All the inputs must be used as clear contacts because the power supply
is generated inside (safe power) the control panel, and it has been laid
down in such a way to guarantee a double or strengthened insulation in
relation to the parts with dangerous power.
- Eventual external circuits connected to the outputs of the control board
or of the expander card must be carried out making sure that a double
or strengthened insulation is used in relation to parts with dangerous
power.
- All inputs are run by a programmed integrated circuit which does a self
check every time it starts operating.
< 95% without condensation
230V~ ±10% (on request 120V
±10%)
50/60 Hz
60 mA
100ms
3W lamp or to 5
LEDS with 2,2 k
resistance In series)
40W with resistive load
200mA 24Vac
G G
B B

Publicidad

Tabla de contenido
loading

Tabla de contenido