Mechanical Seal Replacement - Flotec FP5712 Manual Del Usuario

Bomba de refuerzo de varias etapas
Ocultar thumbs Ver también para FP5712:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance

Mechanical Seal Replacement

(refer to Figures 8 and 9)
This procedure is best completed with the pump held in
a vertical position, motor down.
First complete "Disassembly" instructions 1 through 5
under "Impeller Stack Replacement." (see Figure 8).
6. Remove 4 capscrews holding pump body to motor.
Pump handle will come off with top capscrews.
7. Unscrew pump shell from pump body, turning clock-
wise (left hand threads).
8. Remove mechanical shaft seal spring and rotating
half from motor shaft. Use care not to scratch motor
shaft when removing rotating half.
9. Remove pump body from motor and place on flat
surface, face down. Again, use care not to scratch
motor shaft.
10. Use a screwdriver to push ceramic seat out from seal
cavity as shown.
11. Installation of ceramic seat:
A. Turn pump body over so seal cavity is up; clean
cavity thoroughly.
B. Clean polished surface of ceramic seat with a
clean cloth.
C. Lubricate outside rubber surface of seat with soapy
water. Place cardboard washer over polished face
8
Rotating Half
of Mechanical
Seal
Figure 9 – Mechanical seal replacement.
For parts or assistance, call Flotec Customer Service at
12. Installation of rotating half and spring:
13. To complete reassembly from this point, reverse
7
Remove shell;
turn clockwise.
10
Push ceramic
seat out of
pump body
9
Remove
Pump Body
11
3/4" pipe or
3/4" socket
with extender
6
Ceramic Seat
of seat and press into seal cavity using a 3/4" sock-
et or a piece of 3/4" standard pipe.
D. Be sure polished surface of seat is free of dirt and
has not been damaged by insertion. Remove
excess soapy water. Dispose of cardboard washer.
A. Reinstall pump body on motor using extreme cau-
tion not to hit ceramic portion of seal on motor
shaft. Reattach pump body to motor using cap-
screws. Be sure to reinstall pump handle at this
time.
B. Inspect shaft to make sure that it is clean.
C. Clean face of rotating half of seal with a clean
cloth.
D. Lubricate inside diameter of rotating half with
soapy water and slide onto motor shaft (sealing
face first).
E. Place spring over motor shaft so it rests on rotating
half.
instructions 1 through 5 under "Impeller Stack
Replacement."
NOTICE: Lubricate suction and discharge O-Rings
with soapy water for easier installation of shell.
Rotating
Half
12
Cardboard
washer (supplied
w/seal)
Polished
Face
Torque bolts to
15 - 27 Ft-lbs
during
reassembly.
1212 0605
1-800-365-6832