Maintenance
General
Hazardous voltage and risk of cord
damage . Can shock, burn, or kill. Before removing the
pump from the basin for service, always disconnect
electrical power to the pump and the control switch.
Do not lift the pump by the power cord. See the Cord
Lift Warning.
After removing the basin cover and the necessary
discharge piping, lift the pump out of the basin.
Place the pump in an area where it can be cleaned
thoroughly. Remove all scale and deposits on the pump.
Submerge the complete pump in a disinfectant solution
(dilute chlorine bleach) for at least one hour before
disassembling the pump.
The pump motor housing contains a special lubricating
oil which should be kept clean and free of water at
all times.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
Impeller Replacement
See Repair Parts for assembly view.
1. Remove the three capscrews holding the lower
motor housing to the volute; lift off the lower
motor housing. Do not remove the three capscrews
that fasten the motor cover.
2. Unscrew the impeller by turning it counter-
clockwise. Remove impeller and replace it.
3. Reassemble the pump (reverse instructions 1 and
2 above.)