Descargar Imprimir esta página

Hilti HIT-ICE Manual De Instrucciones página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Hilti HIT-ICE
The mortar dispensed with the first two trigger pulls (initial flow from the nozzle) is not
suitable for making fastenings and must not be used. Dispose discarded anchor adhesive
into the empty outer packaging. Likewise, after changing a mixing nozzle, the first two trigger
pulls must be discarded.
Inject anchor adhesive from the back of the borehole without forming air voids:
Inject the anchor adhesive starting at the back of the hole (use the extension for deep
holes), slowly withdraw the mixer with each trigger pull. Fill holes approximately 2/3 full, or
as required to ensure that the annular gap between the anchor/rebar and the concrete is
completely filled with anchor adhesive along the embedment length.
After injection is completed, depressurize the dispenser by pressing the release trigger.
This will prevent further anchor adhesive discharge
Insert anchor/rebar into bore hole. Mark and set anchor/rebar to the required embedment
depth.
Before use, verify that the anchor/rebar is dry and free of oil and other contaminants. To
ease installation, anchor/rebar may be slowly twisted as they are inserted. After installing an
anchor/rebar, the annular gap must be completely filled with anchor adhesive.
Observe the gel time "t gel", which varies according to temperature of base material. Minor
adjustments to the anchor/rebar position may be performed during the gel time. See table
11. Once the gel time has elapsed, do not disturb the anchor/rebar until the curing time
"t cure" has elapsed.
Apply designed load/torque after "t cure" has passed, and the fixture to be attached has
been positioned. See table 12.
Hilti accepts no liability for damage or failure caused by:
– Storage and transport not in accordance with the specified conditions.
– Failure to observe the instructions for use and setting data, incorrect use
– Inadequate design of the anchor points, inadequate load bearing capacity of the base material
– Other influences of which Hilti is not aware or on which Hilti has no influence,
e.g. use with products from a third party.
10
Printed: 19.08.2016 | Doc-Nr: PUB / 5098739 / 000 / 03

Publicidad